User Mode; Ignition Of The Stove; Run Mode; Stove In Operation - Bio Bronpi Elsa Instructions D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
Time and Date
Chrono Enable
Radio Room Temperature
Combustion Power
Heating Power
Air Flow Direction
Mon 13:22
Ignition
18º
22º
º
D50
Mon 13:22
Radio
Room
Thermostat
Set: 25º C
D52
10.3.5.

THE ROOM TEMPERATURE REACHES THE TEMPERATURE FIXED BY THE USER

When the room temperature reaches the value fixed by the user or the smoke temperature reaches a value
too high, automatically, the stove starts working at a lower power. The stove modulates. See drawing D53.
If after this time, the room temperature continues increasing, the stove turns off and it will turn on again when
the room temperature is below the temperature set point.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
San 14:26
D
Off
18º
20º
º
M
M
L
R
Remote
10.3.

USER MODE

The normal operation of the remote control is explained below according the
functions available.
Before the ignition, the screen of the remote control shows the message of
drawing D49. It only shows the room temperature and the current time.

10.3.1. IGNITION OF THE STOVE

In order to ignite the stove, simply press the key
Firstly, the stove carries out an initial check-up and continues the ignition
process. After this, the display shows the message "IGNITION" (see drawing
D50).
The maximum duration of the ignition phase is 20 minutes. If after this time
there is not flame, the stove will automatically activate the alarm state and the
display will show the alarm message "Er12".

10.3.2. STOVE IN OPERATION

Once certain smoke temperature has been reached, the hot air fan starts
working and the leds will light up according to the power of the fan. Once
the ignition phase has been finished, the stove enters into "Run Mode" which
represents the normal operating mode (see drawing D51).
The display shows the time, the working power and the room temperature.

10.3.3. ADJUSTMENT OF THE ROOM TEMPERATURE

In the initial screen, by pressing the keys
temperature desired for the room. This modification is only possible in the
initial screen, inside the user menu. This option is inside a specific menu. The
value introduced is automatically saved in the memory when you exit from this
option or pressing the key SET (see drawing D52).

10.3.4. POWER SET-UP

This option is only available inside the user menu. See section 10.4.1.1.
Battery Charge
Er02
Error Code
State System
Room Radio Thermostat
Radio Configuration
D48
during a few seconds.
it is possible to select the
37
Mon 13:22
OFF
18º
22º
º
D49
Mon 13:22

Run Mode

18º
22º
º
D51
Mon 13:22
Modulation
18º
22º
º
D53
ELSA

Publicité

Table des Matières
loading

Table des Matières