Emerson InSinkErator F-HC1100 Manuel Du Propriétaire page 9

Masquer les pouces Voir aussi pour InSinkErator F-HC1100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FILTRATION INFORMATION
The InSinkErator Instant Hot Water Dispenser Filtration System offers two levels
of filtration, depending on the filter used: F-1000S is intended for use in filtering
particulates, chlorine taste and odor from drinking water, and has not been evaluated
for other uses; F-2000S reduces particulates, chlorine taste and odor, plus cysts,
lead, mercury, asbestos, benzene, atrazine, 2,4-D, Lindane, Carbofuran and
p-Dichlorobenzene. The system is typically installed (near or beneath a sink) where
filtered drinking water is desired, and must be installed, operated and maintained as
specified in the installation and use instructions.
To reduce the risk associated with property damage due to water leakage or flooding:
NOTICE
• Read and follow Use Instructions provided with the original system before installation
and use of this product.
To reduce the risk of water leakage or flooding, and to ensure optimal filter performance:
• Change the disposable filter cartridge every six months or sooner if you
observe a noticeable reduction in water flow rate.
• Failure to replace the disposable filter cartridge at recommended intervals may
lead to reduced filter performance and cracks in the filter housing, causing
water leakage or flooding.
• For systems using two handle HC model faucets, operate only one handle
at a time.
• For questions or concerns, please contact Customer Service at
1-800-558-5700.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
F-1000 Cartridge (included with this system) Chemical & Mechanical Reduction Filter Specifications:
This cartridge provides mechanical and chemical reduction of chlorine taste & odor and particulate class III.
Tested & Certified by NSF International against NSF/ANSI Standard 42 in the following
InSinkErator Systems Only: GN1100, HC1100, GN2200, HC2200, GN2215, HC2215,
H3300 or HC3300 for the reduction of claims specified on the Performance Data Sheet.
For systems using two handle HC model faucets, operate only one handle at a time.
Filter Capacity: 500 gallons, depending on local water conditions. Note that while the testing was performed under
standard laboratory conditions, actual performance may vary. Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the system. For cold water use only. Systems must be
installed and operated in accordance with the Manufacturer's recommended procedures and guidelines. See warranty
card for warranty. For service and parts, contact your local dealer or InSinkErator
2.1 mg/L
2.0 mg/L ± 10%
Nominal
At least 10,000
270,000 pts/mL
Particulate Class III,
particles/mL
≥5 µm to <15 µm
Application guidelines/Water Supply Parameters for NSF Testing: Service flow of 0.75 gpm, community or
private well water supply, water pressure of 20-120 psi (138-827 kPa), water temperature of 33˚F–100˚
noted, all testing performed at pH = 7.5 ± 0.5, Flow: 0.75 gpm, Pressure: 60 psi, Temp: 20˚± 3˚C.
Refer to the Performance Data Sheet for InSinkErator Filter System Model F-2000S
Replacement Cartridge: F-2000
Contact an authorized InSinkErator service agent for repairs or replacement components. Replacement filters
F-1000 and F-2000 can be ordered by calling 800-558-5700, visiting shop.insinkerator.com, or by contacting
an authorized InSinkErator reseller.
16
Pressure: 30-120 (207-827 kPa) psi
Temperature: 33
º
F - 100
º
F
Flow Rate: 0.75 gpm
Capacity: 500 gallons
®
directly at 1-800-558-5700.
0.06 mg/L
97.0%
≥ 50%
J-00082587
82 pts/mL
99.9%
≥85%
J-00119308
F Except as
Please read Troubleshooting Guide and/or visit
www.insinkerator.com before calling AnswerLine
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Water and steam spits
• Unit is boiling.
forcefully from spout
May be normal during initial setup.
without turning on the
dispenser faucet.
Water is not hot.
• The unit is unplugged.
• The electric outlet is inoperative.
Water is too hot
• Thermostat is not adjusted to
or not hot enough.
your needs.
Water comes out the
• Outlet tube is blocked.
vent instead of spout.
Water is dripping from
• The expansion chamber isn't draining
the spout/vent
properly due to low water pressure.
intermittently.
• The spout is blocked.
Water is dripping
• Debris in the water line may be
from the spout/vent con-
in the faucet valve seat causing a
stantly.
slow water leak.
Divided stream.
• Debris in the end piece.
Water discoloration/rusty
• Corrosion of unit.
appearance.
FILTRATION ISSUES
Water taste or odor.
• Filter needs to be flushed out.
• Life of filter has expired.
New filter leaks or
• Head and bracket not fully rotated.
doesn't fit.
• Filter O-ring breach.
No water flow or
• Life of filter has expired.
low water flow.
If you are still experiencing trouble call the AnswerLine
®
WHAT TO DO
• Activate faucet lever to release some water from
the tank.
• Adjust water temperature using dial on tank front.
Remember that at higher altitudes, water boils
at lower temperatures.
• Make sure the unit is connected to a properly grounded
electric outlet.
• Make sure the circuit breaker or fuses are
functioning properly.
• Check that the outlet is not switched off.
• Adjust the thermostat slowly, then activate faucet lever for 20
seconds to bring in fresh water to be heated at the new setting.
Allow 5-7 minutes for water to reach new temperature.
• Check that outlet tube is not kinked, twisted or pinched.
• Unscrew spout end piece and clean out any debris.
• Unplug the unit. If the dripping doesn't stop after a few
minutes, check the supply valve to ensure that is fully
open and there are no obstructions in the water line
reducing the pressure below 30 psi (i.e., a poorly mounted
saddle valve, a clogged water filter, or a partially opened
shut-off valve).
• Unscrew spout end piece and clean out any debris.
• Unscrew spout end piece and clean out any debris.
• Activate faucet lever 7-10 times to flush faucet & lines.
• Unscrew spout end piece and clean out any debris.
• Unplug and drain unit as described in the Seasonal
Storage/Drainage Section on page 15 of this manual. If the
water discoloration remains after draining and refilling unit,
discontinue use and contact an authorized InSinkErator
service agent.
• Activate the faucet lever and run until the water is cold.
If there is no change, replace filter cartridge.
• Remove, inspect, reinstall filter cartridge.
• Remove new filter, replace with old filter. Check operation.
If OK, reinstall new filter and recheck operation.
• Replace filter cartridge. See page 15.
1-800-558-5700.
®
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Insinkerator f-gn1100Insinkerator f-hc2200Insinkerator f-gn2200Insinkerator f-hc2215Insinkerator f-gn2215Insinkerator f-hc3300 ... Afficher tout

Table des Matières