5
INSTALLING FILTRATION SYSTEM
a
Personal Injury: Do not locate filter above an outlet or other
electrical device. Install head and bracket so that connections
require no stretching, kinking or pinching of tubing.
b
1
from water
2
supply line
NOTICE
Property Damage: Tube runs need to form to the cabinet's
contours to allow storage space with no sharp bends. Tubes
need clean, perpendicular, burr-free cuts to ensure a true fit.
c
HC1100, HC2200,
GN1100, GN2200, GN2215,
HC2215
HC3300, H3300
3
Plug
From filter or
From filter or
water supply line
water supply line
NOTICE
Property Damage: Do not extend the lines farther
than the 16" provided. Ensure tube(s) and "Y"
connector are securely fit.
d
1
From water
To dispenser
supply line
It is normal for approximately 2 oz. of water to
discharge when filter is removed.
10
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
Separate cartridge from filter head.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" starter holes and attach bracket
to wall with wood screws, turning until snug.
Insert cartridge into filter head. Top
surface of cartridge will become flush with
bottom of filter head when fully engaged.
Determine length of tubing required,
then cut to length making sure the cut
2
is perpendicular and burr-free.
Insert a white 1/4" tube into inlet side
to dispenser
of filter head until it stops. Press in
again to ensure a secure fit.
Insert the other white 1/4" tube into
outlet side of filter head until it stops.
Press in again to ensure a secure fit.
3
Insert the copper tubes(s) from the
dispenser into "Y" quick-connector
using the plug for hot-only models.
Connect the white 1/4" tube from
the right outlet on the filter head into
the quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
Connect remaining white 1/4" tube to
incoming water supply line.
(See Step 6.)
2
3
6
FINAL WATER CONNECTION
a
Brass Nut
Brass Nut
Brass Nut
Ferrule
Brass Insert
Plastic
Plastic
tube
tube
Property Damage: Join remaining tube
b
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Dispensing Hot Water
(HC3300, H3300)
Brass Nut
Ferrule
Brass Insert
Plastic
tube
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
c
Property Damage: A standard grounded outlet within
30" of the dispenser is required under the sink. Do not
use an extension cord set with the dispenser.
If the water coming from the faucet is not hot 15 minutes after the unit has been
plugged in – or for other issues related to the operation of your instant hot water
Install a T-fitting (not included) onto the cold
Brass Nut
water supply line.
Ferrule
Ferrule
Brass Insert
Ferrule
Install dedicated water control valve with 1/4"
compression fitting.
At the end of the white 1/4" tube from the filter
or quick-connector, slide the supplied brass nut
and ferrule over the tube and then push in the
NOTICE
brass tube insert.
Insert the white 1/4" tube into the 1/4"
compression fitting and tighten.
to cold water supply only.
Turn on water supply.
Open hot water faucet to expel trapped air.
For the F-1000S and F-1000, flush
2.25 gallons through filter before use
(approximately 3 minutes). For the F-2000S
and F-2000, flush 3 gallons through filter
before use (approximately 4 minutes).
Operating Instructions for InDulge
Dispensing Cool Water
(HC3300)
Featuring OptiPush
automatic shut off and cool side Stay-On
keeps the faucet open when dispensing cool water.
HC3300: To dispense instant hot water, first
press down on the faucet handle and then
push the handle backward in the direction of
the red indicator on the top of the handle.
To dispense cool water, first press down on
Brass Nut
Ferrule
the faucet handle and then pull the handle
forward in the direction of the blue indicator
on the handle.
Note: Only applies when handle is mounted on
left side.
Featuring OptiPush
automatic shut off.
H3300: To dispense instant hot water, first
press down on the faucet handle and then
push the handle backward in the direction of
the red indicator on the top of the handle.
Check all connections to ensure they are tight
and that there are no leaks.
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
NOTICE
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
dispenser – refer to the "Troubleshooting" section on Page 17.
Modern Faucets
TM
hot side activation with
™
, which
™
hot side activation with
™
11