System Setup (continued)
(Step #12 continued)
• Press the Mode button again to advance to Hardness. Press
the Up or Down arrow to adjust the setting to the untreated
water hardness. Hardness range is 3-200 gpg.
• Hold the Extra Cycle button until the program icon
disappears to save your programming.
• Press the Mode button again to advance to Capacity Remaining.
This is the amount of gallons the unit can treat. This is not
adjustable.
• If you are just changing one program step, hold the Extra Cycle
button until the program icon disappears to save your changes.
If you do not hold the Extra Cycle button until the program icon
disappears, your changes will not be saved.
NOTE: This unit has a day of the week reserve. It calculates a
reserve for each day of the week based on water usage over the
past four weeks.
Select the salt dose that most accurately reflects the amount
of total iron in the water supply.
Total Iron Range
Salt Dose Setting
System Capacity
Salt Used
Total Compensated
Hardness*
Total Iron Range
Salt Dose Setting
System Capacity
Salt Used
Total Compensated
Hardness*
17
0-1 ppm
3 lbs./cu. ft.
10 lbs./cu. ft.
11,000 grains
21,000 grains
2.8 lbs.
12 gpg
0-1 ppm
3 lbs./cu. ft.
10 lbs./cu. ft.
14,000 grains
28,000 grains
3.6 lbs.
17 gpg
1-3 ppm
3+ ppm
15 lbs./cu. ft.
25,000 grains
8.4 lbs.
12.7 lbs.
25 gpg
30 gpg
1-3 ppm
3+ ppm
15 lbs./cu. ft.
33,000 grains
11.1 lbs.
16.7 lbs.
35 gpg
40 gpg