Closing Direction; Securing The Rod; Start-Up - FAAC B 604 Manuel D'utilisation

Une barrière électromécanique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

4.4. CLOSING DIRECTION

The B 604 automated system is supplied designed for ri-
ghtward closing of the beam, looking at the automated
system from the release device side.
Procedure for modifying the closing direction of the beam:
1.
Unscrew the two screw (Fig. 21 ref.
part of the beam.
Remove the stop plate (Fig. 21 ref.
2.
3.
Re-position the plate you have just removed, and turn it by 180°
with respect to the original position (Fig. 22 ref.
Re-secure all parts with the two screws (Fig. 22 ref. ).
4.
Fig. 21
Fig. 21

4.5. SECURING THE ROD

The pictures below refer to a leftward closing installation. For
a rightward closing installation, the pictures of the door
bearing rod and the release unit must be reversed.
The B 604 automated system can be coupled to three different
types of rod:
Single rod L=4 m.
Telescopic rod L=3.15 m.
Single rod L=3 m with lights or edge in rubber.
All three rods are fastened to the barrier in the same way;
just use the relevant pocket.
To secure the rod, follow the instructions below:
1.
Assemble the rod-carrier plate (Fig.
23 ref.
) with the pocket for the
selected rod (Fig. 23 ref.
using the two rear screws.
2.
Tighten the two screws.
3.
Fit the selected rod between the
pocket and the plate.
There is a hole at the end of the
rod. The hole must be oriented
in order to allow insertion of the
safety screw (Fig. 24 ref.
thus preventing the rod from
slipping down when in vertical
position.
4.
Orient the rod correctly and fit the safety screw.
5.
Complete securing the rod with the other two screws, Fig.25.
6.
Position all these parts on the drive disk (Fig.26 ref.
- for leftward closing - the orientation shown in the figure.
The rod must always be installed vertically, irrespective of
the closing direction.
), which are on the top
).
)
) only
),
Fig. 23
Fig. 23
Fig. 24
Fig. 24
) respecting
Fig. 25
Fig. 25
7.
Check if the rod is perfectly vertical and secure the four nuts.

5. START-UP

Wire the control unit according to your needs, following the
relevant instructions.
Connect the power cable to the
screw terminal inside the motor
body.
To connect the 230/115 Vac
power cable, respect the indi-
cations in Fig. 27
Turn the key to the OPERATION posi-
tion, see paragraph 7.
Power up the system and check
if all connected accessories are
operating correctly, addressing special attention to the safety
devices.
Perform the programming procedure following the instructions
for the control unit.
If necessary, correct the rod position, adjusting the securing nuts
of the rod-bearing plate.
When you have finished programming the control unit, and
controlled correct operation of the automated system, close
the central compartment with the three supplied screws, and
position the covering plugs as shown in Fig. 28.
Position the rear housing of the rod-bearing plate (Fig. 29 ref.
coupling it in the two free holes on the plate (Fig. 29 ref.
Fig. 28
Fig. 28
Re-position the top housing, Fig. 30.
Turn the key to the STOP position, see paragraph 6.
Position the housing that covers the release device, as shown in
Fig. 31, and secure it using the two supplied screws.
Fig. 30
Fig. 30
Turn the key back to the OPERATION position, see paragraph 7.
11
Fig. 26
Fig. 26
Fig. 27
),
).
Fig. 29
Fig. 29
Fig. 31
Fig. 31

Publicité

Table des Matières
loading

Table des Matières