Intended Use; Electrical Voltage - Bühler technologies CPsingle X1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
CPsingle X1, CPdouble X1
1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.

1.1 Intended use

This unit is intended to discharge condensate from cooled
process fluids. The temperature of these mediums is approx. 5
°C.
These operating instructions apply to pressurised encapsula-
tion with surface-cooled electric motors for low voltage, de-
gree of protection IP40, IP54, IP64, IP65 EN
60034-5:2001+A1:2007.
The motor is ignition protection type Ex db, designed for Zone
1 (ATEX and IECEx).
The competent supervisory authority or the operator is re-
sponsible for determining the degree of explosion hazard of
an operating site.
The electric motor may only be used for continuous duty, not
for frequent starting without significant start-up warming.
The pump may be used in explosive areas Zone 1 and 2. Explo-
sion group IIB, temperature class T4.
1.2 Scope of delivery
• 1 x Peristaltic pump
• Product Documentation
1.3 Type plate
Example:
Manufacturer and address
Model designation
Purchase order no.+Item no.+Counter
Blast protection marking
Materials in contact with mediums, operating instructions no.
Temperature specifications
Year of manufacture
2 Safety instructions
This unit may only be used if:
• The product is being used under the conditions described
in the operating- and system instructions, used according
to the nameplate and for applications for which it is in-
tended. Any unauthorized modifications of the device will
void the warranty provided by Bühler Technologies
GmbH,
BX450026 ◦ 09/2018
Bühler Technologies GmbH
Harkortstr. 29
D-40880 Ratingen
CPsingle CPdouble
101001080015 44921123101
II 2G c IIB T4 X
Material: Norprene, doc.no.: BX450026
Medium max: see manual; Tamb: 0°C-60°C
Read manual!
Year: 2017
• The specifications and markings in the type plate are ob-
served,
• The limits in the data sheet and the instructions must be
observed,
• Monitoring equipment / protection devices must be con-
nected correctly,
• Service and repair work not described in these instruc-
tions is performed by Bühler Technologies GmbH,
• Using genuine replacement parts.
Regulation IEC/EN 60079-14 must be observed when erecting
electrical systems in explosive areas.
Additional national regulations pertaining to initial opera-
tion, operation, maintenance, repairs, and disposal must be
observed.
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.
The equipment must be installed by a professional familiar
with the safety requirements and risks.
Be sure to observe the safety regulations and generally applic-
able rules of technology relevant for the installation site. Pre-
vent malfunctions and avoid personal injuries and property
damage.
The operator of the system must ensure:
• Safety notices and operating instructions are available
and observed,
• The respective national accident prevention regulations
are observed,
• The permissible data and operational conditions are
maintained,
• Safety guards are used and mandatory maintenance is
performed,
• Legal regulations are observed during disposal.
DANGER

Electrical voltage

Electrocution hazard.
a) Disconnect the device from power supply.
b) Make sure that the equipment cannot be reconnected to
mains unintentionally.
c) The device must be opened by trained staff only.
d) Regard correct mains voltage.
DANGER
Toxic, corrosive condensate
a) Protect yourself from toxic, corrosive condensate when
performing any type of work.
b) Wear appropriate protective equipment.
c) Please note the national safety rules!
Bühler Technologies GmbH
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cpdouble x1

Table des Matières