3.3

Installation

Where to install
The inverter should be installed in a location that meets the following
requirements:
3-3-1.
Dry – Do not allow water to drip or splash on the inverter.
3-3-2.
Cool – Ambient air temperature should be between -25° and
+40° Celsius.
3-3-3.
Safe – Do not install in a battery compartment or other areas
where flammable fumes may exist, such as fuel storage areas
or engine compartments.
3-3-4.
Ventilated – Allow at least 25 mm of clearance around the
inverter for air flow. Ensure the ventilation openings on the rear
and bottom of the unit and the fan inlets are not obstructed.
3-3-5.
Dust-free – Do not install the Dometic SI1500 Sine Inverter in a
dusty environment where dust, wood particles or other
filings/shavings are present. Dust can be pulled into the unit
when the cooling fan is operating.
3-3-6.
Close to batteries – Avoid excessive cable lengths but do not
install the Dometic SI 1500 Sine Inverter in the same
compartment as batteries. Use the recommended wire lengths
and sizes. Do not mount the Dometic SI1500 Sine Inverter
where it will be exposed to the gases produced by the battery.
These gases are very corrosive and prolonged exposure will
damage the Dometic SI 1500 Sine Inverter.