Installation Codes And Standards - Vulcan VCS18 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Carefully unpack unit(s) and place in the approximate installation position. Make sure to retain parts
packed separately in their own boxes or shipped separately in finishing kit.
Before installing, verify that the electrical service agrees with the specifications on the rating plate located
inside the front door of the unit. If the supply and equipment requirements do not agree, contact your
dealer immediately.
LOCATION
The equipment area must be kept free and clear of combustible substances.
Installation clearances:
The installation location must allow adequate clearances for servicing and proper operation. A minimum
front clearance of 35" (889 mm) is required.
The unit is suitable for installation on combustible floors when 6" (152 mm) adjustable legs or casters are
used. When legs or casters are removed, use only on noncombustible floors, curb, or platform, with front
appliance base projecting 3" (76 mm) beyond curb or platform.
The unit(s) must be installed so that the flow of ventilation air will not be obstructed.
The unit requires connection to a fresh water supply. The unit is provided with a 48" connection hose
with standard ¾" GHT threaded faucet adapter. Do not attempt to modify or replace this hose as it is part
of the safety systems of this unit. If hose is not long enough to reach the water supply, a short hose
extension may be used, or the water supply may be piped to the location of the unit by a licensed plumber.
PURGE AIR FROM LINE PRIOR TO OPERATION TO PREVENT WATER SURGE AND SPLATTER.
This unit may be supplied with an optional gas manifold for insertion into a batteried range lineup. In this
case, ensure that all gas connections are leak free before operations and that only a licensed gas plumbing
technician performs service to the unit.

INSTALLATION CODES AND STANDARDS

Your Vulcan Unit must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Electrical Code ANSI/NFPS-70 (latest edition) available from the National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment , latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Canadian electrical code C22.1 Part 1 (latest edition).
COMBUSTIBLE
CONSTRUCTION
Back:
Right Side:
Left Side:
- 4 -
2"
1"
1"
NON-COMBUSTIBLE
CONSTRUCTION
0"
0"
0"

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vcs36Vcs36d

Table des Matières