ABIROB
W
2 Product Description
2.1 Designated Use
2.2 Use contrary to the designated use
2.3 Technical Data
Ambient temperature of welding
Transport and storage
Relative humidity
Tab. 1
Ambient temperature
Type of voltage
Polarity of the electrodes
Wire types
Type of use
Voltage rating
Protection type of the machine-side connections
Shielding gas (DIN EN 439)
Tab. 2
General torch data according to EN 60 974-7
Type
Type of
cooling
®
ABIROB
W300
liquid
W500
liquid
Tab. 3
Product-specific torch data as laid out in EN 60974-7
1For pulse arcs, the load data are reduced by up to 35%.
The liquid-cooled welding torch system ABIROB
and automatic application. Designated use also includes the observance of the
prescribed operating, maintenance and servicing instructions.
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorized conversions or power increase
modifications are not allowed.
1
Load
ED
Wire ø
CO
M21
2
(A)
(A)
(%)
(mm)
300 300 100 0.8 - 1.2 25
500 500 100 0.8 - 1.6 25
®
- 10 °C to + 40 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
DC
Usually positive
commercially available round wires
automatically
Peak value of 141 V
IP3X (EN 60 529)
CO
and mixed gas M21
2
Gas flow
max.
flow
temp.
(l/min)
(°C)
50
50
2 Product Description
W must be used for robot
Cooling data
min.
Flow pressure
flow
min.
max.
(l/min)
(bar)
(bar)
1.25
1.5
3.5
1.25
1.5
3.5
EN - 5