6.6 Connecting the control lead
On the torch side
Emergency Stop 2
Emergency Stop 3
Emergency Stop 1
Gas nozzle sensor
insulated
Wire feeder
Wire feeder
Fig. 8
Connecting the control lead
6.7 Setting the shielding gas quantity
Ventilate the entire cooling system as follows when used for the first time and
after every cable assembly change:
1 Disconnect the coolant return hose (4) from the re-circulating cooling unit
and hold it over a collecting device.
2 Close the opening at the coolant return hose (4) and open it again by
repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles into the collecting device.
3 Switch off the re-circulating cooling unit and reconnect the coolant return
hose (4).
Control lead with 3-pin plug
101.0140
WH
BN
GN
NOTICE
• The type and quantity of the shielding gas quantity depends on the
welding task and the gas nozzle geometry.
• To prevent the shielding gas supply from becoming clogged by
impurities, the cylinder valve must be opened briefly, before connecting
the cylinder. This will blow out any impurities that may be present.
• Make all shielding gas connections gas-tight.
1 Connect shielding gas cylinder to the wire feeding system.
2 Set the gas quantity on the pressure reducer of the shielding gas cylinder.
6 Putting into operation
Control lead 7-wire
100.0084
WH
BN
GN
YE
GY
BU
PK
EN - 15