Stopping The Generator; Emergency Shutdown - LIFAN Power USA ENERGY STORM LF3500 CSA-CA Manuel D'utilisation

Table des Matières

Publicité

LOW OIL ALARMSYSTEM:
This model is equipped with a Low Oil Alert System designed to avoid engine damage from insufficient oil in the
crankcase. The Low Oil Alarm System will stop the engine automatically before the oil level in the crankcase drops
below safe operating levels.

STOPPING THE GENERATOR:

Refer to Controls and Features section for diagram.

EMERGENCY SHUTDOWN

1. Turn the Fuel Valve to "OFF"position
NORMAL SHUTDOWN
1. Unplug all electrical loads or turn the main breaker to the "OFF"position.
2. In order to stabilize internal equipment temperatures, allow the engine to run for3-‐ ‐ 5minutes under no
load.
3. If the generator will not be in use for more than 7 days, turn the fuel valve to the"OFF" position and allow
the unit to run until the fuel in the carburetor isused and the engine shuts itself off.
4. Turn the ignition switch to the "OFF" position.
5. Allow unit to cool to ambient temperature before storage or transportation.
6. Always transport the generator with the fuel valve in the "OFF" position. Failureto do so will result in
damage to the engine.
Operation of Generator
HOW TO USE YOUR GENERATOR
23