TFA_No. 14.1552_Anleit_09_21
Digital SOUS-VIDE Thermometer
6.3 Housing (Fig. 1)
C 1: Battery compartment
C 3: Magnet
6.4 Probe (Fig. 2)
D 1: Handle
D 3: Cable
7. Getting started and use
• Remove the protective film from the display.
• Plug the connector for the sensor cable into the socket. Make sure the polarity
is correct.
• Cut approximately 2 cm long strip of the foam tape.
• Glue the foam strip to the vacuum bag.
• Insert the probe through the foam strip into the food at a 90° angle and at
least 2 cm to measure its core temperature.
• When preparing steaks: Insert the probe horizontally from the side.
• When preparing meat: Push the probe into the middle of the thickest part, for
poultry between the torso and the thigh; it should touch neither bones nor
cartilage and should not protrude from the meat.
• Caution: The needle probe must remain inserted in the food during the
entire cooking process, as air and water could otherwise enter the pouch
and the vacuum in the pouch could be lost.
• Press the ON/HOLD button.
• The actual core temperature is displayed.
• To activate the hold function press the ON/HOLD button.
• HOLD appears on the display. The actual measured temperature remains on
the display.
• Press the °C/°F button in the HOLD mode to change between °C (Celsius) or
°F (Fahrenheit) as temperature unit.
• In the HOLD mode, the device will turn off automatically after 15 seconds.
• To deactivate the HOLD function, press the ON/HOLD button again.
• The device will turn off automatically after approx. 4 minutes.
• Use the integrated magnet at the back of the device to place it on metal sur-
faces.
8. Care and maintenance
• Clean the device with a soft damp cloth. Do not use solvents or scouring
agents.
• Remove the battery if you do not use the device for a long period of time.
• Keep the device in a dry place.
• Should water or steam enter the device's jack, it could affect the contact with
the probe. Dry the probe connector with a cloth before you connect it to your
instrument.
12
24.09.2021
9:35 Uhr
Seite 7
C 2: Socket
D 2: Probe
D 4: Probe connector
Digital SOUS-VIDE Thermometer
8.1 Battery replacement
• The battery symbol is permanently shown on the display.
Battery OK
➜ Measurements are possible.
Weak battery
➜ Please change the battery. Measurements are still possible.
Empty battery
➜ Measurements are not possible anymore.
• Make sure the unit is powered off before changing the battery.
• Open the battery compartment by turning the lid to the left using a coin and
insert a new battery CR 2032 (+pole above).
• Close the battery compartment by turning the lid to the right.
9. Troubleshooting
Problem
Solution
➜ Press the ON/OFF button to switch on the
No display
instrument
➜ Ensure that the battery polarity is correct
(+pole above)
➜ Change the battery
➜ Ambient temperature is below 0°C
Er1
or above 50°C
➜ Large temperature changes in a short time
Er2
➜ Remove the battery
Er3
(Make sure the unit is powered off).
➜ Recommended waiting time:
at least 60 seconds
➜ Measured temperature is outside the
Display "Hi/Lo"
measuring range
➜ Plug in the sensor cable
➜ Check the contact between plug and
socket, dry it if necessary
➜ Check the contact between plug and socket
Incorrect indication
➜ Check the position of the sensor
➜ Change the battery
13