DAMPER /
DUCT
CONNECTOR
HORIZONTAL DUCT
Remove Vertical Duct Knockout or Horizontal Duct
5
Knockout and attach Damper / Duct Connector with
two (2) screws (supplied).
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
MOUNTING
SCREWS (4)
Run House Power Cable between service panel and
6
hood location. Attach power cable to hood using appropri-
ate connector.
7
Hold the hood in position under the cabinet. Make sure
the damper / duct connector enters the Ductwork and
that the damper opens and closes freely.
Tighten the four (4) Mounting Screws completely to se-
8
cure the hood to the cabinet.
VERTICAL DUCT
KNOCKOUT
KNOCKOUT
HOUSE
POWER
CABLE
DUCTWORK
CONNECT THE WIRING
HOUSE
POWER
CABLE
HE0059
9
Connect House Power Cable to range hood wiring -
BLACK to BLACK, WHITE to WHITE, and GREEN or
BARE WIRE to GREEN Ground Screw.
COMPLETE INSTALLATION
10
Re-install the wiring cover, bottom cover, and filters that
were removed in Step 3.
INSTALL LIGHT BULBS
(1) PUSH IN
Install Halogen Bulbs. Use 120 V, 50 W, shielded halo-
11
gen bulbs - MR16 or PAR16 with GU10 base. Purchase
bulbs separately.
AP1 & RP SERIES
Page 4
GREEN
GROUND
SCREW
(2) ROTATE
CLOCKWISE