Page 10
ENGLISH
3.2.3 Electrical Wiring
1.
The pump motor must be securely and adequately
grounded using the green screw provided. Ground
before attempting to connect to an electrical power
supply. Do not ground to a gas supply line.
2.
Wire size must be adequate to minimize voltage
drop during the start-up and operation of the
pump. See Table 2 for suggested wire sizes.
3.
Insulate all connections carefully to prevent
grounding or short-circuits. Sharp edges on
terminals require extra protection. For safety,
and to prevent entry of contaminants, reinstall all
conduit and terminal box covers. Do not force
connections into the conduit box.
NOTE Since the pump is operated by either an ePump
controller (JEP-R), an AquaLink
an AquaLink Pool Digital Assistant (PDA) or a
Z4 controller, the pump will not be turned on
until it is turned on with one of these controllers.
3.2.4 Installing the Controller
The ePump can be operated by one of three (3)
controllers: the ePump controller (JEP-R), the AquaLink
RS controller (Rev O or later), the AquaLink PDA (Rev
4.0 or later), or the AquaLink Z4 controller.
Controller
(Rear View)
4-Position
DIP Switch
NOTE
The ePump comes with a factory
installed four-wire RS-485 cable.
Figure 4.
Wiring ePump Controller (JEP-R) to
ePump, Regal Beloit Motor
Jandy
Pro Series ePump™ Series Pump | Installation and Operation Manual
®
RS controller,
®
5 4 3 2 1
4 3 2 1
RS485
REMOTE CONTROL
Grounding Lug
Variable-Speed
Pump
The Jandy Pro Series motor model pump comes
equipped with a factory installed four-wire RS-485
cable. This RS-485 cable comes with an additional
shielded wire for grounding. The shielded wire is to
be grounded ONLY at one end, at the Jandy Pro Series
motor model pump. This is pre-installed at the factory.
At the other end, the shielded wire is pretrimmed at
the factory. If you need to cut the RS-485 cable to any
custom length, make sure to peel back and trim the
ground shielded wire. The ePump communicates with
the controllers via a four-wire RS-485 interface.
To install the ePump controller:
NOTE The ePump controller part no. is JEP-R.
1.
Remove power from the ePump by disconnecting
the high voltage lines or by opening any breaker to
which the ePump power is connected.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in
the ePump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
2.
Remove the cover of the ePump junction box and
feed the RS-485 cable into the fitting.
3.
Unplug the RS-485 connector from the ePump.
4.
Attach the four (4) wires in the RS-485 cable to
the RS-485 connector. Match the wire colors with
the positions on the connector: 1- red, 2- black,
3- yellow, and 4- green. See Figure 4.
5.
Insert the RS-485 connector back into the ePump.
6.
Slide dip switches 1 and 2 up, so they are in the
ON position, and slide switches 3 and 4 down, so
they are in the OFF position. See Figure 4.
7.
Connect the other end of the cable to the
controller. Match the colors of the wires with the
appropriate connector positions, as described in
Step 4.
8.
Restore power to the ePump and verify the
operation of the controller.
9.
Refer to the ePump Controller Owner's Manual,
H0311200, to operate the pump.
To install an AquaLink
or later), an AquaLink PDA (Rev 4.0 or later), or an
AquaLink Z4:
1.
Remove power from the ePump by disconnecting
the high voltage lines or by opening any breaker to
which the ePump power is connected.
RS controller (Rev O
®