5.1.5
Optics
The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.
5.2
Analysis
If there is still a problem after the troubleshooting procedures (see section 6), contact RJ distributor
with the following information:
Model, version and serial number of the product.
•
Software version (available in menu Fixture Status & Version)
•
Description of the problem.
•
5.3
LED reaction according to LED temperature
LED temperature
5°C & 65°C
65°C & 75°C
75°C & 90°C
5.4
Thermal protection
In case of thermal protection start :
Remove the LED compartment (See 5.1.4 Dismantling the LED compartment).
•
Control possible overheating indications.
•
Reassemble the LED compartment.
•
Reset the thermal protection by pressing the button.
•
5.5
Adjusting the maximum light output level
The maximum intensity level of the LED source can be adjusted in the Fixture Setup ! Maximum
menu in order to have a consistent fixture fleet. The dimming level is then recalculated depending on
the limitation.
5.6
Exploded view / Spare parts list
* Available on
www.robertjuliat.com
Fan rotation at minimum level
Fan rotation increases progressively
Fan at maximum speed
LED intensity dims to zero output (overheating protection)
DMX and system LED feedback (7) is red and temperature is available
in Fixture Status menu
- 23 -
Fan
EN