Connecting The Device - Thermor Riva 2 Notice D'installation Et D'utilisation

Radiateur sèche-serviettes
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3) Connecting the device

- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using the 3-wire cable factory fitte to the heater , through a
connecting box. In damp premises, such as bathrooms and kitchens, install the connecting box at
least 25cm from the ground..
- The installation must comply with local national regulation. If in doubt, ask the national Atlantic dis-
tributor.
- Ground connection is forbidden.
Do not connect the pilot wire (black) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified elec-
trician using special tools.
- If a heater pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be
protected on this differential.
4) How to connect the mixed version to the water system ?
For the connection of hot water, the mixed version comprises 2 threaded ports 1/2 gas 15/21 F
WALL
CONNECTION
GROUND
CONNECTION
Panel heater cable
Live=brown
Neutral=blue
Pilot wire=Black
Two possible cases
1st case: only one heater
2nd case: multiple heaters
Threaded ports
1/2 GAS 15/21 F
115
mini
122 maxi
SIDE VIEW
LIVE
Electricity
grid
NEUTRAL
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
220-240V insulated cable
2
WATER INLET
1/2 GAS 15/21 F
446
FRONT VIEW
18
MIDDLE OF THE DEVICE
386
80
COVER
WATER OUTLET
1/2 GAS 15/21 F
195

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Th5321705Th5321810Th5321815Th5321715Th5321805