CONNECTING THE PANEL HEATER

Connection rules and regulations
- The panel heater must be supplied with 230V single-phase current at 50Hz.
- The panel heater's power supply must be directly connected to the main supply after the circuit brea-
ker without any intermediate switch.
- The panel heater's power cable must be connected to the main supply via a connection box. In damp
areas, such as bathrooms and kitchens, the connection box must be installed at least 25cm above the
floor.
- An Earth connection is prohibited. Do not connect the pilot wire (black wire) to Earth.
- The installation must be fitted with an all-pole cut-off switch with a contact opening distance of at least
3mm.
- If the power cable is damaged, it must only be replaced by an electrician.
- If you are using the pilot wire and it is protected by a 30mA differential (e.g.: bathroom use), the pilot
wire's power supply must also be protected on this differential.
Wiring diagram for the heating panel
-
Cut off the power supply and connect the wires as shown in the following diagram:
- You can connect the pilot wire if your home is equipped with a programming unit or controller.
In this case, make the following checks according the selected mode (Comfort, Eco, etc.) to that the
programming instructions are being transmitted correctly:
COMFORT
SIGNAL TO BE
TRANSMITTED
MEASUREMENT
BETWEEN THE
0 Volt
PILOT WIRE
AND NEUTRAL
Panel heater cable
Phase=brown
Neutral=blue
Pilot wire=Black
Three possible cases
1st case: only one heater
2nd case: Slave heater
3rd case: Master heater
ECO
FROST
-115 Volts
230 Volts
negative
25
PHASE
Electricity
grid
NEUTRAL
The pilot wire end is insulated
and not further connected
To the appliance with cassette or
programming unit.
To pilot wire of an electronically
controlled appliance
COMFORT
SWITCH-OFF
OF HEATING
AND POWER
CUT-OFF
+115 Volts
230 Volts
positive
for 3 s
COMFORT
-1°C
-2°C
5'
5'
3''
7''
230 volts
for 7 s
GB