Testing For Leaks; Service Interval - Porter Cable PXCMLA4708065 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CLEANING THE AIR FILTER
A dirty air filter will reduce the compressor's
performance and life. To avoid any internal
contamination of the pump, the filter should be
cleaned frequently, and replaced on a regular
basis. Felt filters should be cleaned in warm,
soapy water, rinsed, and allowed to air dry before
reinstallation. Paper filters should be replaced
when dirty. Do not allow the filter to become filled
with dirt or paint. If the filter becomes filled with
paint, it should be replaced. Direct exposure to
dirty conditions or painting areas will void your warranty.
CHECKING THE RELIEF VALVE
Pull the relief valve daily to ensure that it is operating properly and to clear the
valve of any possible obstructions.

TESTING FOR LEAKS

Check that all connections are tight. A small leak in any of the hoses, transfer
tubes, or pipe connections will substantially reduce the performance of your air
compressor. If you suspect a leak, spray a small amount of soapy water around
the area of the suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not overtighten any connections.
STORAGE
Before storing the compressor for a prolonged period, use an air blow gun to
clean all dust and debris from the compressor. Disconnect the power cord and
coil it up. Pull the pressure relief valve to release all pressure from the tank. Drain
all moisture from the tank. Clean the filter element and filter housing; replace the
element if necessary. Drain the oil from the pump crankcase and replace it with
new oil. Cover the entire unit to protect it from moisture and dust.
Perform the following maintenance at the intervals indicated below.
Inspect and clean air filter ......................................................................Weekly
Check pump oil level ...................................................................................Daily
Change pump oil .................................................... Every 200 operating hours
Operate the pressure relief valves .............................................................Daily
Check belt tension ................................................. Every 250 operating hours
Drain tank .....................................................................................................Daily
Check and tighten all bolts ...........................................After first 8 hours and
(Do not overtighten)
MAINTENANCE

SERVICE INTERVAL

Use synthetic blend, non-detergent air compressor oil.
18- ENG
H = Wingnut
I - Metal cover
J = filter element
every 500 operating hours