Prior To Operation; Installation; Connecting The Suction Line; Discharge Port - Metabo HWW 3000/20 g Instructions D'utilisation

Masquer les pouces Voir aussi pour HWW 3000/20 g:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
ENGLISH
"Technical Specifications"). Com-
pletely unroll cable reels.
Do not buckle, squeeze, drag or
drive over power cable and exten-
sion cables; protect from sharp
edges.
Place extension cable so that it can
not get into the fluid to be pumped.
Unplug:
 prior to all servicing;
 when persons are in the swim-
ming pool or garden pond.
A
Danger by pump failures!
If you notice transport damage while
unpacking,
notify
your
immediately. Do not operate the
pump!
Before each use check the pump,
especially the power cable and plug
for possible damage. Risk of fatal
electric shock!
A damaged pump must be work-
manlike repaired before it can be
used again.
Do not attempt to repair the pump
yourself! Only trained specialists are
permitted to service or repair pumps
or pressure vessels.
A
Caution!
To avoid water damage, e.g.
flooded rooms, caused by pump mal-
functions or defects:
provide for suitable safety measures
such as the following:
 alarm or
 collection tank with monitoring.
The manufacturer is not liable for any
damage caused by:
 improper use of the pump;
 overloading of the pump through
continous operation;
 failure to operate and store the
pump in a frost-free environment;
 unauthorised modification of the
pump (repairs to electrical equip-
ment may only be carried out by
qualified electricians!);
 use of spare parts which have not
been tested and approved by the
manufacturer; or
 use of unsuitable installation materi-
als (fittings, connection lines etc.).
Suitable installation materials:
 pressure-resistant (min. 10 bar)
 heat-resistant (min. 100°C).

5. Prior to Operation

The pump is easily assembled and con-
nected. 
If in doubt, contact your specialist sup-
plier or a qualified electrician.
12
5.1

Installation

 The pump must be placed on a
plane and level surface, suitable of
bearing the weight of the pump fully
filled with water.
 To avoid vibrations the pump should
be placed on an elastic base.
 The installation location should be
well vented and protected from
atmospheric exposure.
 When operated at garden ponds
and pools the pump must be set up
safe against flooding and safe-
garded against falling into the water.
Any additional legal requirements
are to be observed.
5.2
Connecting the Suction
supplier
Line
3
Note: 
Possibly further accessories may
be required for connection (see "Availa-
ble Accessories").
A
Caution! 
The suction line needs to be
installed in such manner that it does
not exert mechanical force or distor-
tion to the pump.
Caution! 
A
When pumping contaminated
fluids install a suction strainer to pro-
tect the pump from sand and dirt.
Note: 
3
A check valve is recommended to
prevent water backflow when the pump
is turned off.
 All screw fittings must be sealed
with thread sealing tape; leaks
cause the priming of air, which
reduces or completely prevents the
priming of water.
 The suction line should have an
inner diameter of 1" (25 mm) mini-
mum and must be kink and vacuum
resistent.
 Keep suction line as short as practi-
cal, as with increasing length the
pump capacity is reduced.
 The suction line should ascend
towards the pump to prevent air
locks.
 A sufficient water supply must be
ensured, the foot valve at the end of
the suction line must be submerged
in water at all times.
5.3

Discharge Port

3
Note: 
Possibly further accessories may
be required for connection (see "Availa-
ble Accessories").
Caution! 
A
The discharge (or pressure)
line needs to be installed in such
manner that it does not exert mechan-
ical force or distortion to the pump.
 All screw fittings should be sealed
with thread sealing tape to prevent
leakage.
 All parts of the pressure line must be
resistant to internal pressure.
 All parts of the pressure line must be
installed in a workmanlike manner.
Danger! 
A
Improper installation and use
of parts not resistant to internal pres-
sure can cause the pressure line to
break during operation. Risk of per-
sonal injury by liquid spurting from
the line under high pressure!
5.4
Connection to a Pipe
System
A stationary installation (e.g. in an indoor
domestic water system) is also possible.
 To reduce vibrations and noises the
pump should be connected to the
pipe system with flexible tubing.
5.5

Connection to AC Power

Danger! Risk of electric shock! 
B
Do not operate the pump in wet
environment and only under the fol-
lowing conditions:
 Connect only to an earthed outlet
that is properly installed, earthed
and tested.
 Mains voltage and fuse protection
must
correspond
requirement stated in the "Tech-
nical Specications".
 When operated at pools, garden
ponds and similar locations, the
pump must be protected by a
residual current operated device
(RCD, 30 mA) (DIN VDE 0100 -702,
-738
or
equivalent
local regulations). 
We recommend the use of RCD's
as a general precaution for per-
sonal protection.
 When operating the pump out-
doors the electrical connections
must be splash-proof; the con-
nections must not be placed into
water.
 Use only extension cables of suf-
ficient lead cross section (see
"Technical Specifications"). Com-
pletely unroll cable reels.
5.6
Filling the pump and
priming
Caution! 
A
After installation, loss of water
or priming of air the pump needs to
be filled with water. Starting the pump
without water causes damage!
with
the
applicable

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hww 4000/20 gl

Table des Matières