Conversion to another type of gas
Adjusting the gas valves
9
WARNING
Risk of damage!
Do not over-tighten the bypass screws.
If necessary, adjust the bypass screws M using a Torx
screwdriver (see table):
up: The bypass screws must be flush with the top edge of
the frame.
down: The bypass screws must be screwed in fully.
Assembly:
1.
Connect the connection cable on the back of the
control panel.