THE ELECTRONIC CIRCULATOR
(low-consumption pump)
The product has a circulator with an electronic motor to save
electricity and comply with the European regulations.
Electronic control of operation:
a) Control mode p – c
In this mode, the electronic controller keeps the differential
pressure generated by the pump at a constant set value of H s.
Pressure differential
b) Control mode p – v
In this mode, the electronic controller varies the pressure
differential between the set value Hs and 1/2 H s. The pressure
differential varies with the volume fl ow.
Pressure differential
c) Venting procedure
This procedure allows the expulsion of air present in the
hydraulic circuit.
After manual selection of the "AIR" mode, the pump will
automatically alternate between maximum and minimum speed
for 10 minutes.
At the end of the procedure, the circulator will go to the pre-set
speed. You can then select the desired mode of operation
INSTRUCTIONS FOR USE
Volume fl ow
Volume fl ow
We summarize the signals that low-consumption circulators
can display with the LEDs located on the pump controls
The green
Green led
LED
led fl ash
on
quickly
MEA-
Working
NING
pump
WORK
The pump
The pump
CONDI-
works in
works 10
TION
base of its
minutes
settings
to purge
the air.
After it is
necessary
to set the
power
CAUSE
Normally
Normally
work
work
RESO-
LUTI-
VE AC-
TION
- 71
-
The led
The led
fl ash with
fl ash with
Led off
light red/
red light
green
The pump
Pump out
No supply
is ready to
of service
voltage
work but
doesn't
turn
The pump
The pump
The pump
will start
is stopped
doesn't
to work
(blocked)
receive
automa-
the vol-
tically
tage
when the
problem
is solved
- under-
The pump
- The
voltage U
doesn't
pump
< 160V
start auto-
isn't con-
overvol-
matically
nected on
tage U >
the mo-
253V
therboard
- Engine
- The led
tempera-
is defec-
ture too
tive
high
- The
pump is
defective
- Check
Change
- Check
the vol-
the pump
the wire
tage
connec-
195V < U
tion
< 253V
- Check
- Check if
the water
the pump
tempera-
works
ture
- Change
the pump