Procedure
1.
Make sure that the basin is empty /
the condensate water has been
pumped out.
2.
Make sure that the discharge hose
(optional) and the mains cable
have been disconnected from the
appliance.
3.
Transport the dehumidifier to where
it is going to be used.
NOTE: The air must circulate freely. Do
not cover the air openings. There must
be a clearance of at least 1 m in front of
the air outlet and the air filter.
AD 750: Preparing the basin
Does not apply if an optional discharge
hose is connected.
Procedure
Slide the basin into the dehumidi-
fier.
AD 750-P/AD 780-P: Connecting
the discharge hose
With the AD 750-P/ AD 780-P it is es-
sential to connect the discharge hose
provided.
ATTENTION! Inadequate appliance
output!
Do not bend the discharge hose.
Do not place any objects on the
hose.
Procedure
1.
Attach the discharge hose on the
back of the device to the discharge
nozzle and secure with the hose
clamp.
2.
Run the discharge hose away from
the dehumidifier to a drain or into a
suitable container (maximum height
difference: 3 m).
AD 750: Connecting an optional dis-
charge hose
If necessary, the condensate water in
the AD 750 can be drained off via a dis-
charge hose instead of into the basin.
To do this, proceed as follows:
ATTENTION! Inadequate appliance
output!
Do not place the end of the hose in
the water (backwater possible).
Do not bend the discharge hose.
Do not place any objects on the
hose.
Procedure
1.
Remove the basin.
2.
Attach a suitable hose (12 x 2 mm)
to the discharge nozzle (Pos. 1) us-
ing a pipe clip.
3.
Make sure that the end of the hose
is lower than the start of the hose
at the discharge nozzle. Minimum
slope of 5% (5 cm/metre).
4.
Run the end of the hose into a
drain or a suitable container.

Electrical connection

Procedure
1.
Make sure that the supply voltage
is the same as the connection volt-
age in the technical data.
2.
Provide an adequate fuse for the
socket and the power supply.
3.
Install an earth leakage circuit
breaker in damp rooms and build-
ing sites.