Télécharger Imprimer la page

Dimensions - Hella marine NaviLED PRO 3 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

PR
O
ASSEMBLY AND REMOVAL INSTRUCTIONS
NaviLED
PRO Navigation Lamps
®
Assembly
Allow for
cable
Step 1
Make Provision for the power cable
Markings
Step 2 - Mount the Shroud
2.1 Shroud must be installed with markings on
the TOP horizontal surface.
2.2 Arrow on top of shroud must point;
Right ahead for Port and Starboard lamps
Right astern for Stern lamps
Right ahead for Masthead lamps
Shroud
Optic Assembly
Step 3 - Insert the Optic Assembly
Note - Arrow on top of Shroud and Arrow on top of
Optic Assembly must point in the same direction
3.1 Feed power cable
3.2 Push optic assembly into Shroud
3.3 Connect power
Removal
Step 1
Insert screw driver between Optic
Assembly and Shroud
Step 2
Pull Optic Assembly out
The NaviLED
PRO
®
BSH certified range
With UV resistant PMMA Lens
Description
NM
Black Shroud
White Shroud
Port Lamp
2 NM
2LT 959 900-501
2LT 959 900-511
Starboard Lamp 2 NM
2LT 959 908-501
2LT 959 908-511
Stern Lamp
2 NM
2LT 959 909-501
2LT 959 909-511
Masthead Lamp 3 NM
2LT 959 940-501
2LT 959 940-511
With Ultra High Impact Resistant Polyamide Lens
Description
NM
Black Shroud
White Shroud
Port Lamp
2 NM
2LT 959 900-601
2LT 959 900-611
Starboard Lamp 2 NM
2LT 959 908-601
2LT 959 908-611
Stern Lamp
2 NM
2LT 959 909-601
2LT 959 909-611
Masthead Lamp 3 NM
2LT 959 940-601
2LT 959 940-611
www.hellamarine.com
PR
O
BSH certified NaviLED
225° Masthead Navigation Lamp
Housing Description
UV resistant PMMA or Polyamide lens, High impact shroud
Light Source
Multiple LEDs
Installation
Pre-wired with 2.5m of marine cable
Operating Voltage
Multivolt
9-33 volts DC
TM
Voltage Protection
Spike protected to +500 volts
Reverse Polarity protected to -700 volts
Power Consumption
Less than 2.5W
Protective System
IP 67, Completely sealed
Electromagnetic Compatibility (EMC)
This LED lamp is an electronic device. The electrical circuits contain components that
suppress possible interference, both emission as well as susceptibility, to the limits
prescribed in EN 60945.
Protection against damage due to voltage spikes
This lamp is protected against reverse polarity connection and negative voltage spikes of
up to 700 volts.

Dimensions

57 mm
87.0 mm
Wiring Colour Coding
LED modules are polarity conscious.
Reverse polarity will not damage this product but will inhibit its function.
Hella recommends wire connections be soldered, and heat shrink tubing applied to seal the joint.
Colour
Connect to
Power Consumption
Black
Negative (-ve)
Red
Signal (+ve)
Less than 2.5W
PRO 3 Nautical Mile
®
50.0 mm
90.0 mm
Wiring
- Supply Voltage 9-33V (DC only)
NB: Lamp must be protected
by a fuse rated at 5 amperes
maximum.