WARNING
During the operation regime of heating, the lever must not be set to "Shut input of air" "0"; it could bring about
a sudden inflammation of fuel.
5.4.2. Ignition without the air control EASY CONTROL
• First, insert chunks onto the bottom of combustion chamber or onto the grid, by size (approx. 1.5 to 2.0 kg).
Then, put a solid fire-lighter cube on the chunks, and a small amount of fine wood onto the top. The above
mentioned amount of the wood is ONLY for heating.
• All air slide valves (primary and secondary air regulators) must be fully opened. After flooding, the
combustion chamber door must be closed. The heating process depends on the draft of the chimney. Once
the complete fuel starts to burn, the "Primary Air Regulator" slide valve must be closed.
5.5. Stoking of fuel
The fuel should be laid on live embers only (without flame).
5.5.1. Chimney stove with EASY CONTROL
• Before opening the door of the fire box, the lever should be brought to the position "Input of air closed" 0", in
order to avoid the escape of combustion products to the living room.
• After stoking of fuel, close the door of the fire box again.
• Next, set the lever to the position "Ignition" again ON, so that the time interval to the inflammation of fuel
might be as short as possible.
• As soon as fuel starts burning lively, the lever is to be re-set again to "Heating operation regime".
5.5.2. Chimney stove without EASY CONTROL
• Before opening the firebox door, all registers should be closed, in order to minimize the escape of flue gases
into the living space.
• After having added fuel (concerning the max. admissible quantity), close the firebox door shut again.
6
Combustion air
1 - Primary air controller
2 - Secondary air controller
3 - Tertiary air