Inlet Of Combustion Air; Input Connection Of External Air(Provided It Is Installed); Operation Of The Fireplace Stove; Suitable Fuels - Haas+Sohn RLU-CDIN 18897 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Recommended protection of the floor:
A 50 cm – in the front
B 30 cm – from the inside edge of the combustion space
C see the type plate – extent of radiation from the window
Safety distances from inflammable construction parts:
In the rear - see the type plate
On the side - see the type plate
In the front in the extent of radiation - see the type plate

4.2. Inlet of combustion air

It is necessary to ensure that in the place of location of the stove there would be available sufficient
combustion air.

4.3. Input connection of external air(provided it is installed)

Note
We recommend to employ an input connection of external
air for the supply of combustion air, so that precious air
from the living room might not be consumed during
heating.
WARNING
We do not recommend to bring cold air from outside to the
room by means of direct conduction; it could bring about
formation of condensate.

5. Operation of the fireplace stove

5.1. Suitable fuels

The fuels approved for combustion and the maximum stoking amounts of fuel are shown in the specification of
the appliance.
The length of the fuel varies from 29 cm to 33 cm, depending on the combustion chamber.
Orientating value (depending on the type of the wood):
1kg of fire wood = about 4kW
4