Fitting
28,8-58-77*
6,4
48,8
*for 30-60-80 hob
The unit must be installed so that the mains plug is easily
accessible.
Connection
These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with
publication CEI 83 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged, it must be replaced by the manufacturers, their After Sales Service or another
similarly qualified person for avoiding any possible risk of accident.
When
the
power
is
code appears on the control panel. This disappears automatically after
about
30
seconds
panel. This is normal, as the display is for use by the after-sales service when required. The user must not
take this into account under any circumstances.If the unit has a 3 phase 400 V2N connection, and is not
working correctly, check that the neutral wire is correctly connected. This precaution should also be taken
for all your other electronic apparatus.
- 230 V monophase
fuse 32/16 Amp
Green/yellow
brown
L
N
10:34
Page 7
Installing your hob in complete safety
51
26,3-55,5-74,5*
dimensions in cm
switched
on,
or
after
or
as
soon
as
any
Blue
Black
L
N
7
A seal exists for preventing any
humidity getting under the hob.
-Stick the seal under the rim of
the hob and lower the hob into
position on the worktop.
-This seal is supplied in the
sachet; stick it in place beneath
the hob.
Fix the clips into position
(supplied in the sachet).
a
long
power
failure,
touch
control
is
touched
- 400 V 2N three-phase
fuse : 16 Amp
brown
Blue
L2
N L1
Separate the 2 phase wires L1 and L2
before connecting
a
light
on
the
Green/yellow
Black

Publicité