VOLCANO
VR Mini
VOLCANO
VR1
VOLCANO
VR2
VOLCANO
VR3
VOLCANO
VR-D Mini
VOLCANO
VR-D
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
electricity consumption**
horizontal air stream range
vertical air stream range
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
electricity consumption**
horizontal air stream range
vertical air stream range
EN
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
electricity consumption**
horizontal air stream range
vertical air stream range
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
electricity consumption**
horizontal air stream range
vertical air stream range
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
horizontal air stream range
vertical air stream range
fan speed
air flow
noise level for Volcano AC*
noise level for Volcano EC*
AC motor electric power**
EC motor electric power**
horizontal air stream range
vertical air stream range
Volcano VR Mini
III
m³/h
2100
dB(A)
52
dB(A)
50
W
115
W
95
W
91
m
14
m
8
Volcano VR1
III
m³/h
5300
dB(A)
56
dB(A)
54
W
280
W
250
W
202
m
23
m
12
Volcano VR2
III
m³/h
4850
dB(A)
56
dB(A)
54
W
280
W
250
W
226
m
22
m
11
Volcano VR3
III
m³/h
5700
dB(A)
57
dB(A)
55
W
410
W
370
W
355
m
25
m
12
Volcano VR-D Mini
III
m³/h
2330
dB(A)
49
dB(A)
50
W
115
W
95
m
16
m
10
Volcano VR-D
III
m³/h
6500
dB(A)
58
dB(A)
56
W
410
W
370
m
28
m
15
28
II
I
1650
1100
42
29
40
27
68
48
56
39
32
5
* reference conditions: room volume 1500m³,
measurement taken at a distance of 5m.
8
5
** EC motor electric power for the air flow mentioned in the table
5
3
*** Standard laboratory conditions
II
I
3900
2800
51
40
49
38
220
190
190
162
75
41
* reference conditions: room volume 1500m³,
measurement taken at a distance of 5m.
20
15
** EC motor electric power for the air flow mentioned in the table
9
7
*** Standard laboratory conditions
II
I
3600
2400
51
40
49
38
220
190
190
162
* reference conditions: room volume 1500m³,
89
45
measurement taken at a distance of 5m.
** EC motor electric power for the air flow mentioned in the table
19
14
*** Standard laboratory conditions
8
6
II
I
4100
3000
51
45
49
43
320
245
285
218
123
55
* reference conditions: room volume 1500m³,
measurement taken at a distance of 5m.
22
17
** EC motor electric power for the air flow mentioned in the table
9
7
*** Standard laboratory conditions
II
I
1830
1220
39
27
40
27
68
48
56
39
* reference conditions: room volume 1500m³,
measurement taken at a distance of 5m.
10
7
** EC motor electric power for the air flow mentioned in the table
7
5
*** Standard laboratory conditions
II
I
4600
3400
52
45
50
43
320
245
285
218
* reference conditions: room volume 1500m³,
measurement taken at a distance of 5m.
24
19
** EC motor electric power for the air flow mentioned in the table
11
9
*** Standard laboratory conditions