ATEX units
Ex d unit (ATEX certification No. Baseefa02ATEX0224X)
Certified to EN60079-0, EN60079-1 and EN60079-31
Ex d IIC T4 (-55°C to +85°C)
Ex tb IIIC T135°C (-55°C to +85°C) Db IP6x
Ex d IIC T5 (-55°C to +55°C)
Ex tb IIIC T100°C (-55°C to +55°C) Db IP6x
Ex d IIC T6 (-55°C to +40°C)
Ex tb IIIC T85°C (-55°C to +40°C) Db IP6x
Ex de unit (ATEX certification No. Baseefa02ATEX0224X)
Certified to EN60079-0, EN60079-1, EN60079-7, EN61241-0, EN61241-1
Ex de IIC T4 (-50°C to +55°C)
Ex de IIC Ex tD A21 IP6X T135°C (-50°C to +55°C)
Ex de IIC T5 (-50°C to +40°C)
Ex de IIC Ex tD A21 IP6X T100°C (-50°C to +40°C)
The ATEX certificate and product label carry the ATEX group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G
Signifies suitability for use in the presence of gases
D
Signified suitability for use in the presence of dust
The ATEX and IECEx units also have the following EMC approvals
Electro-static discharge (DC and AC) to EN61000-6-2:2005 / IEC61000-4-2:1995 +A1:1998 & A2:2000
Radiated Field Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-3:2002 + A1:2002
Electrical Fast Transients/Bursts (DC and AC) to EN61000-6-2:2005 / IEC61000-4-4:2004
Surge Immunity (DC and AC) to EN61000-6-2:2005 / IEC61000-4-5:1995 + A1:2000
Conducted Immunity (10V) to EN61000-6-2:2005 / IEC61000-4-6:2005 + A1:2004 & A2:2006
Dips and Interruptions (AC) to EN61000-6-2:2005 / IEC61000-4-11:2004
Conducted and radiated emissions (AC) to EN61000-6-3:2007
Mains harmonics (AC) to EN61000-6-3:2007 / IEC61000-3-2:2006
01/18