Manufacturer's recommendations:
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free form dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place.

Technical characteristics:

Nominal absorbed voltage ..............................................................1200Watts
Voltage use: European standard......................................... 230/245 Volts 50H
Voltage use: North American standard..................................... 208 Volts 60Hz
Minimum voltage of the power supply .............................................. 198 Volts
(Below this charge = ignition failure is possible).
Voltage at the terminals of the lamp .................................................. 100 Volts
Amperage at the terminals of the lamp ...........................................13,8 Amps
Luminosity of the lamp .................................................................. 110 000 L's
Luminous effectiveness ...................................................................... 90 Ln/W
Colour temperature ....................................................................... 5600 Kelvin
Base ......................................................................................................... G 38
Manufacturer's rated life................................................................... 750 hours
User's precautions:
• The lamplife, as given by the manufacturer, is an theoretic lamplife duration as "in laboratory conditions" a cycle
based on 3 hours on / 1 hour off, cycles more brief, reduce the duration of the lamplife.
• In operating conditions it is uncommon for the lamp to be still working after 200 to 300 hours. Its efficiency can
decrease 30%.
• Premature wearing of lamp under performing conditions, is mainly due to frequent switching on. Better to leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lamplife is reduced about
1 hour, each time the lamp is lighten ).
• Theoretically the lighting unit is designed for instant restricts, but it is still advised to wait for 10 minutes before
switching on again. ( This extends the duration of the lamp.)
• Use over 300 hours of the lamp : change the lamp even thou it still lights up.
New lamp:
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.
14
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thellle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
DOSSIER TECHNIQUE
HMI PROFILE 1200W & 2500W

ADMISSIBLE LAMPS :-

OSRAM : HMI 1200W / SE - HMI 2500W / SE.
PHILIPS : MSR 1200 HR - MSR 2500 HR.
HMI 1200
Thank you.
900 SNX
VALID SINCE : 03.06.02
HMI 2500
2500Watts
230/245 Volts 50Hz
208 Volts 60Hz
198 Volts
115 Volts
25,6 Amps
240 000 L's
90 Ln/W
5600 Kelvin
G 38
500 hours