Velleman VDPL5X5RGB Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Mounting the Device
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour without
deforming.
The installation must always be secured with a secondary attachment e.g. a safety cable.
Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified
technician check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used... Have the material and the device itself checked regularly. Do not attempt to install
the device yourself if you lack these qualifications as improper installation may result in injuries.
Make sure there is no flammable material within a 0.5 m radius of the device.
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered directly off a grounded
switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or dimmer channel
is used solely for 0 % to 100 % switching.
The VDPL5X5RGB has a power output to supply power to another VDPL5X5RGB. When connecting several
VDPL5X5RGBs in a daisy chain via this output, make sure that the total current does not exceed the power
line's nominal current. Use power cables with an adequate section
The installation has to be approved by an expert before the device is taken into service.
DMX-512 Connection
When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the other
side to the male XLR input of the VDPL5X5RGB. Multiple VDPL5X5RGBs can be linked through serial linking.
The linking cable should be a dual core, screened cable with XLR input and output connectors.
A DMX terminator is recommended for installations where the DMX cable has to run a long distance or is in
an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital control
signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor between pins 2
and 3, which is then plugged into the XLR output socket of the last device in the chain.
7.
Operation
The device can be used in the following modes:
built-in programmes (stand-alone or master/slave)
sound activation (stand-alone or master/slave)
DMX (stand-alone or master/slave).
7.1
Control Panel Navigation
The control buttons are located directly underneath the display [4]. From left to right:
Button
Function
MENU
to access the menu, quit the current function without saving the setting, or quit the menu
UP
to scroll upward in a list of functions or options, or increase a value
DOWN
to scroll downward in a list of functions or options, or decrease a value
ENTER
to confirm and save a selected option or value
Menu name
Addr
DMX address setting and channel mode
rL--
gL--
bL--
FLAS
FAdE
ASC-
CE--
V. 01 – 21/08/2014
VDPL5X5RGB
Mode
red
green
blue
shutter
fade
colour macro
programme
5
Function
A001-A512/1CH
B001-B512/3CH
C001-C512/5CH
D001-D512/25CH
E001-E512/75CH
rL00
gL00
bL00
FL00
FA00
AS00 (first set rL, gL, bL at max. value)
CE00
©Velleman nv