Wiring Diagram

Connection to the mains from the transformer should
only be carried out by qualified electrician.
1. Transformer (not included in basic package)
equipped with fuse (class 2, USA/Canada)
secondary voltage: 24 V, capacity: minimum 20 VA
2. Rectifier.
3. Circuit breaker, activated by stop pin,
mounted on the extraction hood.
4. Electro magnet, mounted on the guide bracket.
Connect the rectifier to secondary side of the trans-
former (24V). Then connect the single phase mains
supply to the primary side of the transformer.

Fan Selection

Fans are not included in the basic
package. For the best results, one
fan per extraction unit is recom-
mended, each connected so that
it is controlled by opening and
closing the garage door. It is also
possible to connect several units
to a central fan.
The following Nederman fans are
suitable for installation with the
exhaust extraction system.

Installation Checklist

When the mechanical assembly, fan connec-
tion and electrical installation of the exhaust
extraction unit is complete, the system is
ready for use after double- checking the
following points.
Check that the guide brackets of the extraction
unit do not catch any part of the vehicle.
Check, after disconnection, that the extraction
unit remains up to the safety stop and that the
guide brackets are fully opened.
Check, after disconnection, that the track
returns to its neutral position in the guide
tracks.
Check that the garage door can open freely
without interference with the track.
ENGLISH
1
2
Part No. 510122
Motor output:
0,75 kW
2800 r/m
Rotation speed:
Power supply:
110-120V / 200-240 V
1-phase, 50 Hz
Part No. 510422
Motor output:
0,75 kW
Rotation speed:
2800 r/m
Power supply:
200-240 / 380-420 V
3-phase, 50 Hz

WARNING!

Damage to the product can result if the
exhaust extraction system is not used
and maintained in the proper manner.
The system must not be used when
working on the vehicle´s fuel system,
when recharging the batteries or when-
ever there is a risk for inflammable dust
or explosive gases.
~
24 V
3
Part No. 510222
0,75 kW
3400 r/m
115V / 230 V
1-phase, 60 Hz
Part No. 510522
0,75 kW
3400 r/m
200-240 / 380-420 V
3-phase, 60 Hz
4
6