4. Fit the safety stop with the bolt
supplied in the leading edge of
the track.
5. Screw the hose connector on the extraction unit (NB! Positioned
with the arrows in line, see figure). Drill four holes 3,5 mm dia. and
use the screws supplied with the unit.
6
6. Insert the extraction unit into the track and adjust the position of the
guide brackets sideways and vertically with the exhaust pipe positioned
according to the figure. The guide brackets fit exhaust pipes with a
diameter from minimum 70 mm to maximum 200 mm.
7. Suspend the hose up by threading the carriers into the guide track.
Make sure the carriers are installed in a straight line and that they
do not foul in the track joints.
8. Connect the hose onto the extraction unit by using the hose
clip. Connect the cable from the hose to the cable connectors
from the connection box on the extraction unit.
9. Install the spigot into the bottom edge of the rail and attach
the hose using the clip.
10. Install the rectifier on the bottom edge of the rail
and connect the cable from the hose.
11. Install the disconnection plate to the front part
of the track 0,5 m from the end of the track.
ENGLISH
M10
5
Exhaust pipe
6
min. 70 mm
max. 200 mm
7
8
~ 0,5 m
=
=
6
Guide
brackets
10
9
5