ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and
which respects them scrupulously.
 Protection against the parts under tension must be ensured after the builting-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the
hob or even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
400V~ 50/60Hz
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6/1990
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the
terminal
Monophase 230V~ 1P+N
Put a bridge between terminal 1 and 2, 2 and 3 then a bridge between 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 5 (or 4), the Phase L to one
of the terminals 1 2, or 3.
Biphase
400V~ 2P+N
st
Put the 1
bridge between terminal 1 and 2, the 2
Attach the earth to the terminate "earth", the neutral N to terminal 5 (or 4), the Phase L1 to the
terminals 2 and the Phase L2 to the terminal 3.
Triphase
400V~ 3P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminate "earth", the neutral N to terminal 5 (or 4), the Phase L1 to the
terminals 1, the Phase L2 to the terminal 2 and the Phase L3 to the terminal 3.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phases + N
2 Phases + N
4 x 2.5 mm²
3 Phases + N
5 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
3 x 4 mm²
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between 4 and 5.
15
Protection calibre
40 A *
25 A *
16 A *