Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installation, Operation and
Maintenance Manual
OneFlow
+ Salt-Free Scale
®
Prevention and Water Filtration
System
Model OFPSYS
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
If you are unsure about installing your Watts
contact a Watts representative or consult a professional plumber.
You are required to thoroughly read all installation instructions and
product safety information before beginning the installation of this
product. FAILURE TO COMPLY WITH PROPER INSTALLATION
AND MAINTENANCE INSTRUCTIONS COULD RESULT
IN PRODUCT FAILURE WHICH CAN CAUSE PROPERTY
DAMAGE, PERSONAL INJURY AND/OR DEATH. Watts is not
responsible for damages resulting from improper installation and/
or maintenance. Local building or plumbing codes may require
modifications to the information provided. You are required to
consult the local building and plumbing codes prior to installation.
If this information is not consistent with local building or plumbing
codes, the local codes should be followed.
Save manual for future reference.
Refer to the enclosed for operating parameters to ensure proper
use with your water supply.
• Use only lead-free solder and flux for sweat-solder connections,
as required by state, province and federal codes.
• Handle all components of the system with care. Do not drop,
drag or turn components upside down.
• Be sure the mounting surface the OneFlow
is clean, level and strong enough to support the weight of the
system while in operation.
• Install the system in a protected area.
• Do not attempt to treat water over 100°F (38°C) with the system.
• Always connect the system to the main water supply pipe before
the water heater.
• Do not expose the system to freezing temperatures. Water
freezing in the system causes equipment damage.
• Do not install in direct sunlight. Ultraviolet rays from the sun may
cause damage.
• Do not use on water that is microbiologically unsafe or of
unknown quality.
OneFlow
+ system
®
®
+ will be installed on
®
OneFlow
+ OFPSYS
®
system is certified
by the Water Quality
Association (WQA) to
NSF / ANSI Standard
372 for lead free.
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
+ Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
®
Equipment Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Feed Water Chemistry Requirements. . . . . . . . . . . . . . . . . . . . . . 3
Contaminant Treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Notes to the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
+ System Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
®
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Changing the Filter Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Note to the Home Owner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Introduction
The OneFlow
+ system is an economical and
®
environmentally friendly physical water treatment technology
that protects pipes, extends the life of appliances, and
provides better tasting water through filtration. The
OneFlow
+ system is a dual cartridge-based system with a
®
radial flow 20 micron carbon block cartridge which reduces
sediment, chlorine taste and odor, and an integrated
OneFlow
scale prevention cartridge.
®
The OneFlow
+ system uses template assisted
®
crystallization to attract dissolved hardness minerals and
convert them into harmless, inactive microscopic crystal
particles.
These crystals stay suspended in the water and have a
greatly reduced ability to react and attach to surfaces like
dissolved hardness does. They eventually find their way
to a drain. The system requires very little maintenance, no
backwashing, no salt and no electricity.
The OneFlow
+ system is not a water softener. It does
®
not add chemicals to the water. It is a scale prevention
device with proven third party laboratory test data and
years of successful residential installations. The OneFlow
system is the intelligent scale solution and is a great salt-
free alternative to water softening (ion exchange) or scale
sequestering devices.
IOM-OFPSYS
OFPSYS
Pages
+
®

Publicité

Table des Matières
loading

Sommaire des Matières pour Watts OneFlow OFPSYS

  • Page 1: Table Des Matières

    ® contact a Watts representative or consult a professional plumber. Installation Instructions ....... . 4 Changing the Filter Cartridges .
  • Page 2: Setup

    OneFlow + treatment, may reverse its anti-scale treatment ® effects and/or create water with a heavy residue or spotting Watts OneFlow + systems are complete, self-contained, loaded ® potential. Any adverse conditions caused by the addition of soaps, with media and ready to use. A simple inlet and outlet connection chemicals, or cleaners are the sole responsibility of the end user.
  • Page 3: Feed Water Chemistry Requirements

    For applications with copper concentration greater than 1.3 ppm, please consult Watts • Use PTFE tape on all external pipe threads. Do not use pipe Water Quality Technical Service. To further minimize any joint compound.
  • Page 4: Oneflow ® + System Parts

    Installation Instructions OneFlow + System Parts ® New system comes with the cartridges and outlet connector pre- installed. Installer should verify this prior to installation. How to install your OneFlow + system can also be found at: ® http://thescalesolution.com/residential NOTICE Please remove all items from carton.
  • Page 5: Changing The Filter Cartridges

    Changing the Filter Cartridges: Diagram B Diagram A 1. Turn off the inlet and outlet valves on the system’s supply and outlet lines. 2. Use the Multifunction Tool (Item 6) to release air from the system. This is done by taking the tool and unscrewing the Pressure Relief Valve (Item 5) –...
  • Page 6: Note To The Home Owner

    Note To The Home Owner Things to watch for: During the first 30-90 days: Your OneFlow + system will improve the properties of water ® throughout your home. Here are some things to expect and • Faucet aerators and drains may plug occasionally as old scale some recommendations for maximizing the benefits and your is removed from your plumbing system and water heater.
  • Page 7: Ordering Information

    Ordering Information ONEFLOW + COMPLETE SYSTEM ® Ordering Code Model Number Description 7100638 OFPSYS Scale Prevention and Water Filter System ONEFLOW ® + WATER FILTER REPLACEMENT 7100639 OFPRFC Radial Flow Carbon Block Cartridge 7100640 OFPSP Scale Prevention Cartridge 7100641 OFPCOM Scale Prevention and Carbon Block Combo Pack ONEFLOW + SYSTEM REPLACEMENT PARTS...
  • Page 8: Limited Warranty

    8. Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment of warranty adjustment is made. 9. Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value and of then current production.
  • Page 9 ® póngase en contacto con un representante de Watts o consulte a un Instrucciones de instalación......4 fontanero profesional.
  • Page 10: Configuración

    Toda condición adversa causada por agregar jabones, productos químicos o limpiadores es responsabilidad exclusiva del Los sistemas OneFlow + de Watts son completos, autónomos, ® usuario final. cargados con medios filtrantes y listos para usar. Todo lo que se requiere para la instalación es una simple conexión de entrada y salida.
  • Page 11: Requisitos Químicos Del Agua De Alimentación

    1.3 ppm, comuníquese utilice compuesto para juntas de tuberías. con el Servicio Técnico de Calidad de Watts Water. Para minimizar aún más cualquier problema relacionado con el exceso de cobre, • El peso completo del sistema de fontanería debe ser soportado por evite aplicar fundente en exceso en las superficies internas de la soportes de tuberías u otros medios.
  • Page 12: Piezas Del Sistema Oneflow

    Instrucciones de instalación Piezas del sistema OneFlow ® El nuevo sistema viene con los cartuchos y el conector de salida preinstalados. El instalador debe verificar esto antes de la instalación. También puede encontrar cómo instalar su sistema OneFlow + en: http:// ®...
  • Page 13: Cambio De Los Cartuchos De Filtro

    Cambio de los cartuchos de filtro: Diagrama B Diagrama A 1. Cierre las válvulas de entrada y salida de las líneas de suministro y salida del sistema. 2. Utilice la herramienta multifunción (elemento 6) para liberar aire del sistema. Esto se hace tomando la herramienta y desatornillando la válvula de alivio de presión (elemento 5);...
  • Page 14: Nota Para El Propietario De La Vivienda

    Nota para el propietario de la Detalles para tener en cuenta: vivienda Durante los primeros 30 a 90 días: • Los aireadores y desagües del grifo pueden taponarse ocasionalmente Su sistema OneFlow + mejorará las propiedades del agua en toda ®...
  • Page 15: Información Sobre Pedidos

    Información sobre pedidos SISTEMA COMPLETO ONEFLOW ® Código de pedido Número de Descripción modelo 7100638 OFPSYS Sistema de filtración de agua y prevención de sarro REEMPLAZO DEL FILTRO DE AGUA ONEFLOW ® 7100639 OFPRFC Cartucho de bloque de carbono de flujo radial 7100640 OFPSP Cartucho de prevención de sarro...
  • Page 16: Garantía Limitada

    8. Las piezas defectuosas están sujetas a inspección por parte de Watts Regulator Company o cualquier representante autorizado antes de que se realice el compromiso final de ajuste de garantía. 9. Watts Regulator Company se reserva el derecho de realizar cambios o sustituciones en piezas o equipos con material de igual calidad o valor y de producción actual.
  • Page 17: Système De Filtration D'eau Oneflow ® + Antitartre Et Sans Sel

    ® Watts OneFlow +, veuillez contacter un représentant Watts ou consulter ® ® Instructions d’installation ....... 4 un plombier professionnel.
  • Page 18: Configuration

    Toutes réactions négatives causées par Les systèmes OneFlow + de Watts sont complets, autonomes, remplis ® l’ajout de savons, de produits chimiques ou de nettoyants relèvent du média et prêts à utiliser. Seul un simple raccord d’entrée et de sortie uniquement de la responsabilité...
  • Page 19: Exigences Relatives À L'état Chimique De L'eau D'alimentation

    N’utilisez pas de produit de scellement pour tuyaux. veuillez communiquer avec l’équipe d’assistance technique de Watts Water. Pour réduire davantage tout problème d’excès de • Le poids complet du système de plomberie doit être soutenu par cuivre, évitez d’appliquer un débit trop élevé sur les surfaces des hangars à...
  • Page 20: Pièces Du Système Oneflow

    Instructions d’installation Pièces du système OneFlow ® Les nouveaux systèmes sont livrés avec les cartouches et le raccord de sortie pré-installés. L’installateur doit vérifier cela avant l’installation. Vous pouvez également trouver la manière d’installer votre système OneFlow + au http://thescalesolution.com/residential. ®...
  • Page 21: Changer Les Cartouches Filtrantes

    Changer les cartouches filtrantes : Schéma B Schéma A 1. Fermez les vannes d’entrée et de sortie des conduites d’alimentation et de sortie du système. 2. Utilisez l’outil polyvalent (article 6) pour évacuer l’air du système. Cette opération est effectuée en dévissant la soupape de surpression (article 5) – consultez le schéma F.
  • Page 22: Remarque Destinée Au Propriétaire De La Résidence

    Remarques destinées au À surveiller : propriétaire de la résidence Pendant les 30 à 90 premiers jours : • Les aérateurs et les drains de robinetterie peuvent parfois se boucher Le système OneFlow + améliorera les propriétés de l’eau dans toute ® lorsque les dépôts de tartre sont enlevés de votre tuyauterie et du votre maison.
  • Page 23: Informations De Commande

    Informations sur la commande SYSTÈME COMPLET ONEFLOW ® Code de Numéro de Description commande modèle 7100638 OFPSYS Prévention du tartre et système de filtration d’eau REMPLACEMENT DU FILTRE À EAU ONEFLOW ® 7100639 OFPRFC Cartouche de filtre à bloc de charbon et écoulement radial 7100640 OFPSP...
  • Page 24: Garantie Limitée

    LIMITER, TOUTE GARANTIE TACITE DE QUALITÉ MARCHANDE ET DE CONVENANCE À UN USAGE PARTICULIER. Le recours décrit en vertu de cette garantie constitue le seul recours à toute violation de la présente garantie et Watts Regulator Company ne saurait être tenue responsable de tout dommage accessoire, spécial ou indirect, y compris, sans s’y limiter : le transport, la manutention, la perte de profits ou le coût afférent à...

Table des Matières