A. Information on installation
Step 1: (Check content of delivery)
A1
A2
Step 2: (Check installation space)
A3
Step 3: (Installing the guidings)
A4
A1+A2:
Content: 1x pre-installed coffer with upper guiding profi le
and fl oor profi le (see A1)
1x shutter
1x pre-installed angle bracket
2x cylinder head bolt M8x25 (DIN 6912-8.8)
2x cheese-head screw 2.9x19
Note: We recommend to install the insect protection door
with 2 people.
For a full install, you will need the following additional fi xa-
tion material:
(A) 5x countersunk bolt 2.9x16
(B) 2x panhead bolt 3.5x16
(C) 5x panhead bolt 3.5mm (length depends on the
furniture construction)
A3:
Installing the insect protection door is only possible when
measure "X" on the picture is at last 22mm.
Before installation, remove the door, or before measuring,
the aluminium bracket from the fl oor plate.
A4:
First, turn the upper guiding and the fl oor profi le by 90°.
Make sure the strings do not twist. We recommend assem-
bly to take place on an base.
US/GB
7/17