Quick THG 512 Manuel De L'utilisateur page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TECHNICAL DATA - INSTALLATION
GB
MODEL
MOTOR POWER
Motor supply voltage
Maximum pull
Maximum working load
Working load
Current absorption @ working load (1)
Maximum chain speed (2)
Maximum chain speed @ working load (2)
Ø Drum
Motor cable size (3)
Protection circuit breaker (4)
Deck thickness (5)
Weight
(1) After an initial period of use.
(2) Measurements taken with internal drum diameter.
(3) Minimum allowable value for a total length L<20m. Determine the cable size according to the length of the wiring.
(4) With switches designed for direct currents (DC) and delayed-action (thermal-magnetic or hydraulic-magnetic).
(5) On request, shafts and studs can be supplied for greater deck thicknesses.
DIMENSIONS OF MODEL mm ( inch ) - THG 500W
INSTALLATION
BEFORE USING THE CAPSTAN READ THESE INSTRUCTIONS CAREFULLY.
IF IN DOUBT, CONTACT YOUR NEAREST "QUICK
WARNING:
Quick
capstans are designed and made to recover a tender.
®
Do not use the equipment for other purposes.
Quick
shall not be held responsible for damage to equipment and/or personal injury, caused by a faulty use of the equip-
®
ment.
The capstan is not designed for the loads that might occur in extreme weather conditions (storms).
Always deactivate the capstan when not in use.
For improved safety we recommend installing at least two anchor capstan controls in case one is accidentally damaged.
We recommend the use of the Quick
The reversing contactor unit must be installed in a point protected from accidental water contact.
F
Quick
®
reserves the right to introduce changes to the equipment and the contents of this manual without prior notice.
In case of discordance or errors in translation between the translated version and the original text in the Italian language, reference will be made to the Italian or English text.
8
Ø 188 (7
13
/
)
32
427 (16
13
/
)
16
hydraulic-magnetic switch as the motor safety switch.
®
THG 500
12 V
1200 Kg (2645,6 lb)
600 Kg (1322,8 lb)
200 Kg (440,9 lb)
85 A
6,6 m/min (21,6 ft/min)
5,5 m/min (18,0 ft/min)
60 (2" 23/64)
16 mm
50 A
max 50 mm (1" 31/32)
14 kg (30,9 lb)
" DEALER.
®
500 W
24 V
50 A
7,1 m/min (23,3 ft/min)
5,8 m/min (19,0 ft/min)
(AWG 5)
2
40 A
52 (2
3
/
)
64
240 (9
29
/
)
64
THG 500 - REV000A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Thg 524

Table des Matières