Reset anti-fat filter saturation signal (GREEN LED
EN
FLASHING on the control level)
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Touch in a prolonged manner (more than 3 seconds)
the UPPER PART of the control lever, the LED stops
flashing to indicate that the reset of the signal has been
carried out and the hood switches off.
Reset anti-fat filter saturation signal ORANGE (amber)
LED FLASHING
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Touch in a prolonged manner (more than 3 seconds)
the UPPER PART of the control lever, the LED stops
flashing to indicate that the reset of the signal has been
carried out and the hood switches off.
Deactivating the carbon filter saturation signal (for
special applications)
Switch the hood off (see paragraph above "Select the
suction speed power")
Touch in a prolonged manner (more than 5 seconds)
the UPPER PART of the control lever, the LED flashes
in GREEN to indicate that the carbon filter saturation
signal has been deactivated.
To reactivate the carbon filter saturation signal, repeat
the operation. The LED flashes in ORANGE (amber).
31