Replacing The Lamp - AEG SKB41011AS Notice D'utilisation

Masquer les pouces Voir aussi pour SKB41011AS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
Water flows inside the refrig-
erator.
Water flows on the floor.
The temperature in the ap-
pliance is too low/too high.
If the advice does not lead
to the desired result, contact
the nearest Authorised
Service Centre.

8.2 Replacing the lamp

The appliance is equipped
with a long-life LED interior
light.
It is strongly recommended
to use original spare parts
only.
Use LED bulbs (E14 base)
only. The maximum power is
shown on the lamp unit.
Possible cause
Food products prevent the
water to flow into the wa-
ter collector.
The water outlet is clog-
ged.
The melting water outlet is
not connected to the
evaporative tray above the
compressor.
The temperature regulator
is not set correctly.
The door is not closed cor-
rectly.
The food products' tem-
perature is too high.
Many food products are
stored at the same time.
The door has been
opened often.
There is no cold air circula-
tion in the appliance.
1. Using a screwdriver, remove the
screw from the lamp cover.
2. Detach the lamp cover in the
direction of the arrows.
3. Replace the lamp with the one that
has identical characteristics and is
specifically designed for household
appliances.
Solution
Make sure that food products
do not touch the rear plate.
Clean the water outlet.
Attach the melting water out-
let to the evaporative tray.
Set a higher/lower tempera-
ture.
Refer to "Closing the door".
Let the food products temper-
ature decrease to room tem-
perature before storage.
Add less food products at the
same time.
Open the door only if necessa-
ry.
Make sure that there is cold air
circulation in the appliance.
CAUTION!
Disconnect the plug from
the mains socket.
ENGLISH
25

Publicité

Table des Matières
loading

Table des Matières