Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The fitting must be installed, flushed and tested after
the valid norms.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
4
English
®
(flow
®
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 34)

Flow diagram

(see page 34)
with EcoSmart
without EcoSmart
Spare parts (see page 35)
Special accessories
special tool (58085000) order as an extra
Installation putty order as an extra
Operation (see page36)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning
see enclosed brochure.
Test certificate (see page 36)
®
®

Publicité

Table des Matières
loading

Table des Matières