7 Technical specifications

Input data
Type
Measuring range
Direction of rotation
Max. axial load
Max. radial load
Housing material
Shaft material
Output data
E
Output signal
Resolution
Accuracy
(at room temperature)
Accuracy
(over the temperature range)
Repeatability
angle increase
Ambient Conditions
Operating temperature range
Storage temperature range
- marking
- Marked
Vibration resistance acc. to
DIN EN 60068-2-6: 2008
Shock resistance acc. to
DIN EN 60068-2-27: 2010
Protection class to DIN EN 60529
Other data
Supply voltage
Residual ripple of supply voltage
Power consumption
Weight
Note:
Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
1) with mounted mating connector in corresponding protection class
Edition: 2021-02-18
Absolute singleturn
0 .. 360 °
No orientation restrictions
60 N
100 N
Stainless steel
Stainless steel
CANopen protocol or SAE J1939 protocol,
depending on version
14 bit
± 0.1° typ.
± 0.2° max.
± 0.05° / 10 K typ.
± 0.1° / 10 K max.
≤ ± 0.05 °
factory-set (cw / ccw)
- 40 .. 85 °C
- 40 .. 85 °C
EN 61000-6-1 / 2 / 3 / 4
E13*10R00*10R05*14136*00
7.5 mm (5 Hz ≤ f < 8.2 Hz)
2 g (8.2 Hz ≤ f < 2000 Hz)
50 g (11 ms in 3 axes)
IP 67, IP 6K9K (electronics)
1)
9 .. 36 V DC
≤ 5%
< 1.4 W
~ 120 g
HYDAC ELECTRONIC GMBH
HAT 1400 CANopen
Part No.: 669987