Probe-Electrode Positioning; Gas Feeding Line; Gas Train - Riello 40 FS15 Manuel D'entretien

Brûleur gaz à air soufflé
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.2 PROBE - ELECTRODE POSITIONING
~
Probe
D5104

3.3 GAS FEEDING LINE

1
1
– Gas supply pipe
2
– Manual cock (supplied by the installer)
3
– Gas pressure gauge (supplied by the installer)
4
– Filter
5
– Gas pressure switch
6
– Safety valve
7
– Pressure governor
8
– Adjustment valve
M1 –
Gas-supply pressure test point
M2 – Pressure coupling test point
GAS TRAIN ACCORDING TO EN 676

GAS TRAIN

TYPE
MBDLE 407 B01
The gas train is supplied separately, for its adjustment see the enclosed instructions.
2737
47
mm
2
3
M1
CONNECTIONS
CODE
INLET
3970076
Rp 3/4
Ignition electrode
Diffuser
2
WARNING
4
5
6
7
OUTLET
Rp 3/4
Natural gas and LPG
4
GB
Ionization probe
Electrode
3
3
mm
8
D5099
USE
=
M2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3756803

Table des Matières