Servicing the generator

10
Servicing the generator
10.1

Maintenance table

!
WARNING!
Only have maintenance work carried out by specialist personnel who
are familiar with the relevant regulations. Inadequate maintenance may
cause serious hazards.
I
NOTE
Have the following maintenance work performed at regular intervals or
after the specified number of operating hours, whichever is sooner.
Interval
Inspection/maintenance
➤ Change the oil.
In the first month
or after 50 hours.
➤ Change the oil.
Every 250 hours
➤ Clean the engine's cooling system.
➤ Check the valve play and screws. Adjust the valve play and tighten
➤ Check the air filter (chapter "Servicing the air filter" on page 23).
➤ Replace the air filter and fuel filter.
Every 500 hours
➤ Clean the oil filter.
Once a year or
every 1000 hours
The following must be carried out by a HATZ authorised retailer or
Dometic skilled personnel:
➤ Check the fuel injection pump.
➤ Check the vibration damper.