Tools needed for assembly
Figure A
Supplied accessories
Figure B
Installation
Figures: 4 ÷ 50
Please follow the instructions below for installation.
1. Make sure that the ceiling where the unit is to be
installed is structurally sound to support the weight
of the product.
2. Be careful that the anchoring devices do not com-
promise the structural resistance of the ceiling
where the unit is to be installed.
3. Use dowels that can ensure material stays gripped
to the ceiling where the unit is to be installed.
Operation
Caution!!! The information described in this chapter
only relates to use of the VORTICE Code 12829
POT-R regulator. Operation is possible with other
potentiometers provided they have the following cha-
racteristics:
1 - Resistive value 10kOhm
2 - Integrated or external switch (fig.57)
Fans are turned on by means of a switch integrated
into the potentiometer. Start from the stand-by posi-
tion on the knob and turn it clockwise. You will hear
a click when the switch closes and then, when the fan
is switched back on, you will hear a brief buzzer tone
accompanied by a quick ignition of the LED.
The speed setting is continuous. The first half of the
potentiometer full scale is dedicated to adjusting pro-
duct speed in "standard" ventilation (air pushed
toward the floor). The second half of the full scale is
dedicated to "reverse" mode adjustment (air pushed
toward the ceiling). Fan passage from "standard"
ventilation to "reverse" ventilation is highlighted by
two short buzzer tones and two quick ignitions of the
LED, while passage from "reverse" ventilation to
"standard" ventilation is highlighted by a brief buzzer
tone and a quick ignition of the LED (fig.51).
A transition zone (HYSTERESYS ZONE) is indicated
on the potentiometer (fig.52), corresponding to pas-
sage from "standard" ventilation mode operation (at
maximum speed) to "reverse" ventilation mode ope-
ration (minimum speed).
Shut-down occurs by completely rotating the knob in
the counter-clockwise direction. A long buzzer tone
and a long LED ignition will indicate shut-down.
The product can be remotely operated by means of
the VORTICE Code 21200 TELENORDIK ECO remote
control, and the remote controller unit Vort Delta T
WIFI Code 21175.
CAUTION!
Switch off the potentiometer if present to use the
"TELENORDIK ECO" and the "Vort Delta T WIFI".
Cleaning
Figures: 53 ÷ 56.
Before performing any cleaning or maintenance ope-
rations, turn the unit switch off and disconnect its
plug from the power supply.
Electrical connections
Figures: 57 ÷ 58
Dismantling caps
Figures: 59 ÷ 62 (rods 290÷915)
Figures: 63 ÷ 68 (rod 160)