Analog way Di-Ventix DVX8022 Manuel Utilisateur page 75

Masquer les pouces Voir aussi pour Di-Ventix DVX8022:
Table des Matières

Publicité

Di-VentiX™
COMMAND RESPONSE
COMMANDE RÉPONSE
CONTROLS COMMANDS / COMMANDES DU MENU CONTRÔLE
ja
TALA
jb
TALB
jc
TALC
JA
TAON
JB
TBON
JC
TCON
QE
EPD
ye
EPOS
yd
DEMO
yi
EISP
fr
BFCR
fb
BFCB
fg
BFCG
LF
LFAD
lF
lfad
fR
bfcr
fB
bfcb
fG
bfcg
yF
FRAL
xI
I_
xU
VERU
Y
FRES
COMMUNICATION COMMANDS / COMMANDES DE COMMUNICATION
ne
LANE
nr
LANR
ns
LANS
na
ADIP
nw
IPA_
nx
IPB_
ny
IPC_
nz
IPD_
np
PORT
nk
NTMK
nt
TCP
NOTE:
(M) = MAIN output (sortie MAIN).
(P) = PREVIEW output (sortie PREVIEW).
COMMAND DESCRIPTION
DESCRIPTION DE LA COMMANDE
Input number for TALLY1
Input number for TALLY2.
Input number for TALLY3.
TALLY1 status.
TALLY2 status.
TALLY3 status.
2:2 pull down correction.
Erase all memories.
Demo mode.
Auto-lock
Red adjustment of the FADE (M).
Blue adjustment of the FADE (M).
Green adjustment of the FADE (M).
Transition (M).
Transition (P).
Red adjustment of the FADE (P).
Blue adjustment of the FADE (P).
Green adjustment of the FADE (P).
FRAME ALERT
Identification number.
Update version.
DEFAULT VALUE.
Communication port selection
Reset of the LAN parameters.
Store the LAN parameters.
IP address and port selection (for
modification)
First byte of the address selected by the
na command.
Second byte of the address selected by
the na command.
Third byte of the address selected by
the na command.
Forth byte of the address selected by
the na command.
Number of the port (local or remote)
selected by the na command.
netmask.
protocol selection.
TYPE
MIN MAX
Rd/Wr
1
8
1 = input #1.
.......
Rd/Wr
1
8
8 = input #8.
Rd/Wr
1
8
0
1
0 = TALLY1 inactive
Rd
0
1
0 = TALLY2 inactive
Rd
Rd
0
1
0 = TALLY3 inactive
Rd/Wr
0
1
0 = off
Rd/Wr
0
1
1 = erase all memories (automatic reset).
Rd/Wr
0
1
0 = demo mode inactive.
1 = demo mode active.
Rd/Wr
0
1
0 = off
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
0 = fade color
Rd/Wr
0
3
2 = frame 2
Rd/Wr
0
3
4= frame 3................... 7 = frame 6
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
0 = no frame
2 = frame 2
Rd/Wr
0
15
4 = input 1................... 11 = input 8
12 = frame 3................. 15 = frame 6
0
65535 Values displayed in hexadecimal in the device.
Rd
0
65535 Example: VERU104 = version 1.4
Rd
Rd/Wr
0
1
1 = Default value action (automatic reset).
Rd/Wr
0
1
0 = RS232
Rd/Wr
0
1
1 = reset.
Rd/Wr
0
1
1 = store.
0 = all IP address / ports
1 = IP local address / local port
Rd/Wr
0
3
2 = IP remote address / remote port
3 = IP gateway address.
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
local port: 10000 to 10999.
Rd/Wr
0
65500
remote port: 0 to 65500.
Value = number of bit to 0 (from right).
example: 2
Rd/Wr
0
24
Rd/Wr
0
1
0 = UDP
Rd/Wr = Read and write command / Commande de lecture et d'écriture.
Rd = Read only command / Commande de lecture uniquement.
APPENDIX A / ANNEXE A
VALUE /VALEUR
DESCRIPTION
1 = TALLY1 active.
1 = TALLY2 active.
1 = TALLY3 active.
1 = auto.
1 = on.
1 = frame 1
3 = clean cut
1 = frame 1
3 = black
1 = LAN
255.255.255.252
3
255.255.255.248
.............
8
255.255.255.0.............
24
255.0.0.0
1 = TCP
PAGE 75

Publicité

Table des Matières
loading

Table des Matières