A fault, what to do?
Attention!
Repairs must only be carried out by an authorised technician. Improper repairs can lead to risk
of serious injury to the user.
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether
you can remedy the fault yourself by using the following guidelines. You will save yourself the costs of an un-
necessary visit by customer service personnel.
Fault
Cause
The appliance does
The fuse in the house electri-
not start (heat), no
cal installation has tripped/
water flows.
blown.
Power failure or initial
start-up.
The air sensor in the appli-
ance detects air in the water
and momentarily switches
the heating element off.
The desired water
The supply temperature has
temperature leav-
reduced.
ing the tap is no
longer reached.
Water flow-rate is
The filter in either the water
too low.
tap or the showerhead is
clogged.
The filter in the corner regu-
lating valve is clogged.
The water is not
The appliance's automatic
sufficiently warm.
circuit breaker has been
tripped.
Water flow-rate is too high
and/or the cold water supply
temperature is too low.
If the fault could not be eliminated, please call customer service.
20
en
Solution
Check the fuse in the house electrical
installation.
Starts rinsing:
Open the warm water tap and allow
water to flow for at least 30 seconds
(flow-rate at least 2 litres per minute).
Only then (for safety reasons) will the
appliance begin to heat.
Should the appliance not start because
of a reduced flow-rate, remove the
perlator, shower head or similar before
start and repeat the process.
Reduce the water flow on the taps
until the desired water temperature is
reached.
Remove the filter and either
clean it or descale it.
Remove, clean and reinstall the filter.
Circulate water through the appliance.
If necessary, repeat this procedure until
the filter is free of particles.
Get the appliance's automatic cir-
cuit breaker checked by an electri-
cian. Check the permissible supply
temperature.
Use the angle valve to regulate the
flow-rate.
Check the flow-rate limiter or replace
it with a smaller one.
Who
Customer
Customer
Customer
Customer
Servicing
expert
Servicing
expert
Servicing
expert