10
Configuration parameters
1
Analogue input AN1:
P-0 1
Type of thermocouple
0
Type K (-50/1300 °C)
1
Type J (-50/1200 °C)
2
Type S (-50/1800 °C)
3
Type R (-50/1800 °C)
2
Limits of the scale (0/3200 °C or °F):
P-02
This parameter defines the maximum temperature of the kiln.
All parameters which are expressed as percentage values (ON/OFF
hysteresis, proportional band) also refer to this scale.
3
Auxiliary output A1:
P-03
Operating of second relay.
0
Disabled
1
Set the status of the relay at end of cycle
2
Set the status of relay for each segment of the cycle
3
Same operating of both relays for maximum power
4
General alarm (relay N.O.)
5
Band alarm (relay N.O.)
6
Upper deviation alarm (relay N.O.)
7
Lower deviation alarm (relay N.O.)
8
Set the status of relay during the cycle (N.O. at Start and Stop,
Closed during the cycle)
9
General alarm (relay N.C.)
10
Band alarm (relay N.C.)
11
Upper deviation alarm (N.C.)
12
Lower deviation alarm (N.C.)
13
Set the status of relay during the cycle (N.C. at Start and Stop,
Open during the cycle)
14
Control of safety contactor
5
Offset correction for sensor input (-150/150 °C or °F)
P-05
16
- ATR 900/901 User manual