The emitter points of the anti-static bar must not be covered.
Do not cover the type EP-SH-N and P-SH-N(2) anti-static bars at the rear,
a free passage of air is essential to ensure proper functioning.
MaxION
To ensure proper functioning, the sides of the bar must be at least 50 mm, and the rear of the
bar at least 10 mm, away from any metal.
- Do not lay non-shielded high-voltage cables alongside sharp metal parts.
- Do not kink the high voltage cables and do not lay them in sharp curves.
- When connecting non-metal shielded HV cables to a biphase power unit, the HV
cables connected to the various transformers may not be crossed and must be laid at
least 1 cm apart. Non-compliance with this rule will have negative influences on the HV
cable.
Attention:
- Check that the output voltage of the power unit is correct.

5.2.2. Mounting

- Fit the anti-static bar with the emitter points towards the material to be discharged.
- Use the mounting materials included in the supply.
- Make sure the equipment is properly earthed.
(The MaxION is earthed by way of the power unit via the shielded cable)
- Using the assembly clamps supplied, fix the HV cable alongside the machine frame.
- Connect the HV cable to the power unit,
see the power unit manual.
Bars_UM_9752039010_NL_D_GB_F_V3_4
GB
23