English
Cleaning the flue
To access the smoke flue, remove the upper plate, baffle plate made of vermiculite,
and the smoke chicane (steel plate). They should be treated gently.
Remove the smoke converter plate by tilting it backwards and rotating it forward.
Carefully lift the plate out.
Remove the smoke chicane by lifting it up and tilting it backwards.
Pull the smoke chicane out.
Remove dirt and dust and insert in reverse order.
PLEASE NOTE!
Be careful when replacing the smoke converter plate and the smoke chicane.
Malfunctions
Smoke spillage around the door:
This may be due to insufficient draft in the chimney <12Pa
• Check whether the flue or chimney is blocked
• Check whether the hood is switched on and, if so, switch it off and open a win-
dow / door near the stove for a short period.
Soot on glass
May be caused by
• excessively wet firewood
• the damper regulation is too low
Ensure proper heating of the stove when lighting, prior to closing the door