Check Before Lighting; Startup Stage - Ferroli OMEGA PLUS Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.3 Lighting

4.3.1 Check before lighting

Before lighting the stove:
- make sure you have read and understood that given in the manual;
- the hopper must be filled with pellets;
- the combustion chamber must be clean;
- the brazier must be completely free, cleaned of any combustion residuals and correctly fitted in the brazier
holder;
- check hermetic closing of the fire door and ash pan;
- check the connection of the power cable and switching to ON/1 of the switch located on the back of the stove.
- At first startup, remove all the components (instructions/label) that could burn from the stove firebox and glass.
- Any lightings done after long stove idle periods require the renewal of any pellets that have been inside the hopper
for a long time, in being a damp fuel no longer suitable for combustion, and complete cleaning of the combustion
chamber.

4.3.2 Startup stage

To light the stove, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
The stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
The stove carries out the startup stages in sequence according to the procedures defined by the parameters that
manage levels and times, reaching the work condition unless anomalies or alarms occur, according to the following
table:
Status
OFF
START – CLEANING
PREHEAT
PELLET PREFILL
WAITING FLAME
PELLET LOAD
FIRE PRESENT
WORK
MODULATES WORK
BRAZIER CLEANING
WORK
Pr39 (*)
FINAL CLEANING
After a certain time has elapsed, if the fume temperature has not reached the minimum permissible value the stove
goes in alarm status.
- Do not use flammable liquids to light the stove.
- In case of persistent failed lighting, contact the Service Centre
Room temperature
Clock
Dialogue box
Duration
Igniter
-
OFF
Pr33
OFF
Pr34
ON
Pr40
ON
Pr41
ON
-
ON
Pr02
OFF
-
OFF
-
OFF
Pr12
OFF
-
OFF
OFF
Button 'P4'
Output
Devices
Fume
Auger
Exch.
exhaust
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
-
.
40
Conditions for going to next status
ON/OFF
After time Pr33
After timePr34
After time Pr40
After timePr41
Fume temperature > Pr13
After time Pr02
Room temperature < SET temperature
Fume temperature < Pr14
Room temperature < SET temperature
Fume temperature < Pr14
Every Pr03
ON/OFF to switch off
(*) Pr39 starts from when fume T< Pr13