5. Technical data
Phoenix Inverter
Cont. power at 25°C
(1)
Cont. power at 25°C / 40°C
Peak power
Output AC voltage / frequency (adjustable)
Input voltage range
Low battery shut down (adjustable)
Low battery restart & alarm (adjustable)
Battery charged detect (adjustable)
Max. efficiency
Zero-load power
Default zero-load power in ECO mode
(default search interval: 2,5 s, adjustable)
ECO mode stop and start power setting
Protection
(2)
Operating temperature range
Humidity (non-condensing)
Material & Colour
Battery-connection
Maximum cable cross-section
Standard AC outlets
Protection category
Weight
Dimensions (hxwxd, mm)
(hxwxd, inch)
Remote on-off
Automatic transfer switch
Safety
EMC
Automotive Directive
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
12 Volt
12/250
24 Volt
24/250
48 Volt
48/250
250 VA
200 / 175 W
400 W
87/88/88 %
4,2 / 5,2 / 7 W
0,8/1,3/2,5 W
ENCLOSURE
Schuko (CEE 7/4), IEC-320 (male plug included)
2,4 kg/5,3 lbs
86x165x260
3,4x6,5x10,2
ACCESSORIES
STANDARDS
12/375
24/375
48/375
375 VA
300 / 260 W
400 / 350 W
700 W
230 VAC +/- 3% 50Hz or 60Hz +/- 0,1%
9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0 VDC
9,3 / 18,6 / 37,2 VDC
10,9 / 21,8 / 43,6 VDC
14,0 / 28,0 / 56,0 VDC
89/89/90 %
90/90/91 %
5,5 / 6 / 7,5 W
8 / 8,5 / 10 W
0,9/1,4/2,6 W
1 / 1,5 / 2,8 W
25 W
a - f
-40 to +60°C (fan assisted cooling)
(derate 3% per °C above 40°C)
max 95%
Steel chassis and plastic cover (blue Ral 5012)
Screw terminals
10 mm² / AWG8
UK (BS 1363), AU/NZ (AS/NZS 3112)
IP 21
3,0 kg/6,6 lbs
3,9 kg/8,5 lbs
86x165x260
86x172x275
3,4x6,5x10,2
3,4x6,8x10,8
Yes
Filax or Multi Compact
EN/IEC 60335-1 / EN/IEC 62109-1
EN 55014-1 / EN 55014-2
IEC 61000-6-1 / IEC 61000-6-3
2004/104/EC
12/500
12/800
24/500
24/800
48/500
48/800
500 VA
800 VA
650 / 480 W
900 W
1500 W
90/90/91 %
10 / 11 / 13 W
1,2 / 1,6 / 3 W
25mm²/AWG8
6 kg/13 lbs
90x200x300
3,6x8,0x12,0
EN 50498
5